Siemens 5SL4601-7 — 4-Pole MCB (DIN Rail)

Siemens SENTRON 5SL4601-7 MCB, 4P C 1A, 10kA

MPN5SL4601-7
Active

Siemens SENTRON 5SL4601-7, 4-pole miniature circuit breaker, 1 A, C characteristic, 10 kA breaking capacity, 400 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL4601-7 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityResidential buildings/infrastructure
5SL4601-7 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated current (In), AC1 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, DC (max.)72 V
Voltage typeAC
5SL4601-7 — Protection
ParameterValue
Tripping characteristic (trip curve)C
Rated breaking capacity (Icn), per EN 6089810 kA
Rated breaking capacity, per IEC 60947-210 kA
Energy limitation class3
Overvoltage categoryIII
Pollution degree2
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingYes
Touch protectionYes
5SL4601-7 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SL4601-7 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)+55 °C, max. 95% humidity

Product details

The Siemens SENTRON 5SL4601-7 is a 4-pole miniature circuit breaker (3P+N) with a C tripping characteristic, rated 1 A at 400 V AC. It's built for residential and infrastructure panels — think distribution boards in apartment blocks, small commercial, or light industrial feeder circuits. That's the standard you'd expect for a panelboard MCB in a 400 V supply. For a 1 A rating, that's a magnetic trip between 5 A and 10 A.

Mounting position is any — no restrictions on orientation inside the enclosure. The neutral pole is switched (3P+N), so it breaks the neutral along with the phases. That's a requirement in some regional wiring rules and for isolating the entire circuit. Temperature derating is published: at 30 °C the rating is 1 A; at 40 °C it drops to 0.95 A; at 45 °C it's 0.92 A; at 55 °C it's 0.86 A. If your panel runs hot, factor that in — don't load the breaker to its full 1 A nameplate if ambient is above 30 °C.

Frequently asked questions

Will 5SL4601-7 drop into a panel that was specified around 5SL3640-7MB without rewiring?

Both are 4-pole SENTRON MCBs with the same 4-module width (72 mm) and DIN-rail mounting, so physical fit is the same. Verify your required breaking capacity and curve — the 5SL4601-7 is C-curve at 1 A; the 5SL3640-7MB is a different rating and curve.