Siemens SENTRON 5SL4 series, 5SL4604-7 miniature circuit breaker, 4 A, C-curve, 4-pole (3P+N), 10 kA breaking capacity per EN 60898 / IEC 60947-2, 400 V AC, 76 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SL4604-7 — Ratings
ParameterValue
Overvoltage category3
5SL4604-7 — Mechanical
ParameterValue
Width72 mm
Height90 mm
Depth76 mm

Product details

What this 4-pole MCB does on the line

The Siemens 5SL4604-7 is a 4-pole (3P+N) miniature circuit breaker from the SENTRON 5SL4 series, rated 4 A with a C-curve tripping characteristic. The integrated neutral pole switches the neutral conductor, which simplifies wiring in single-phase or three+N distribution boards.

Panel fit and wiring constraints

The 5SL4604-7 occupies 4 width units (72 mm) on a DIN rail, with a depth of 76 mm and an installation depth of 70 mm. It accepts solid or stranded conductors from 0.75 mm² up to 25 mm², with a recommended tightening torque of 2.5 to 3 N·m on the screw terminals.

It is designed for any mounting position, which gives flexibility in tight enclosures. The overvoltage category is 3, and the energy limiting class is 3 — meaning it limits let-through energy effectively for downstream equipment protection. The product carries the standard Siemens compliance documentation for CE, RoHS, and REACH; specific UL or IEC certificates are available on request with the order.

Frequently asked questions

What is the breaking capacity of the 5SL4604-7?

The 5SL4604-7 has a rated breaking capacity of 10 kA per both EN 60898 and IEC 60947-2 at 400 V AC. This is sufficient for most residential and light commercial distribution boards where the prospective short-circuit current is under 10 kA.

What conductor sizes does the 5SL4604-7 accept?

The screw terminals accept solid or stranded conductors from 0.75 mm² up to 25 mm². The recommended tightening torque is 2.5 to 3 N·m.

Where can I buy the 5SL4604-7 and how is it quoted?

The 5SL4604-7 is sourced to order through our independent distribution network. Submit an RFQ for current pricing and availability — we confirm both at quote time for your required quantity and delivery schedule.

Will the 5SL4604-7 fit in a panel designed for the 5SL6606-7YA?

Both are 4-pole SENTRON 5SL series MCBs on the same DIN-rail footprint, so the 5SL4604-7 will physically drop into the same panel position without rewiring. The key difference is the current rating: 4 A (C-curve) versus the 5SL6606-7YA's rating — verify the load requirement before substituting.

MPN