Skip to main content
Siemens 5SL4606-6 — Miniature Circuit Breakers (MCB)

Siemens 5SL4606-6 SENTRON MCB, 3P+N, B Curve, 6A, 10kA

MPN5SL4606-6
Active

Siemens SENTRON 5SL4606-6 miniature circuit breaker, 3P+N, tripping characteristic B, 6 A rated current, 400 V AC, 10 kA breaking capacity per EN 60898 and IEC 60947-2, 4 MW units wide.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SL4606-6 — Ratings
ParameterValue
Overvoltage categoryIII
5SL4606-6 — Mechanical
ParameterValue
Width72 mm
Height90 mm
Depth76 mm

Product details

The Siemens 5SL4606-6 is a SENTRON miniature circuit breaker — 3P+N, B-curve, rated 6 A at 400 V AC, with a 10 kA breaking capacity certified to both EN 60898 and IEC 60947-2. That dual standard matters: EN 60898 covers residential and commercial final circuits, while IEC 60947-2 qualifies it for industrial panel applications where the fault current can hit 10 kA. The 3P+N design switches all three phases and switches the neutral — no separate neutral bar needed downstream.

Panel fit and environmental tolerance

Mounting position is unrestricted — horizontal, vertical, flat — so you can lay out the DIN rail however the gland plate dictates. Sealable with a lead seal, halogen-free and silicon-free — compliant for clean-room or food-processing zones where outgassing matters.

Power loss and auxiliary add-ons

Each pole dissipates 1.9 W at rated current in hot operating state — about 7.6 W total for the 4-pole assembly. That's low enough to skip forced cooling in a typical 12-way distribution board, but worth tallying if you're packing 20+ breakers in a sealed enclosure. The product accepts supplementary devices (shunt trip, auxiliary contacts, alarm switch) on the left side, so you can add remote tripping or status feedback without swapping the base breaker.

Frequently asked questions

How do I get current pricing and availability for 5SL4606-6?

Submit an RFQ through this listing. We source the 5SL4606-6 through independent distribution and confirm current pricing and availability at quote time — no automated stock figures here, because the market moves daily.

Will 5SL4606-6 drop into a panel specified around 5SL4363-7 without rewiring?

Not directly — the 5SL4606-6 is 4 MW wide (72 mm) versus 3 MW (54 mm) for the 5SL4363-7, so it occupies one extra module space on the DIN rail. Both are 76 mm deep and 90 mm tall, so the enclosure depth and height are fine, but you need the wider slot. The 5SL4363-7 is a 3-pole C-curve breaker; the 5SL4606-6 is 3P+N with B-curve, so the wiring topology differs if you relied on a separate neutral bar.

What compliance documentation does Siemens provide for 5SL4606-6?

Siemens SENTRON MCBs carry CE marking for the European market and are designed to meet EN 60898 and IEC 60947-2. The product is halogen-free and silicon-free. For specific declarations (RoHS, REACH, UL file number), the manufacturer's documentation portal provides the current compliance certificates — we can include those with your order on request.

MPN
5SL4606-6