Skip to main content
Siemens 5SL4606-8 — 4-Pole MCB (DIN Rail)

Siemens SENTRON 5SL4606-8 MCB, D-curve 6 A 4-pole 10 kA

MPN5SL4606-8
Active

Siemens SENTRON 5SL4606-8, miniature circuit breaker, 4-pole 3P+N, D-curve, 6 A, 10 kA breaking capacity, 400 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL4606-8 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityResidential buildings/infrastructure
5SL4606-8 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated current (In), AC6 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, DC (max.)72 V
Voltage typeAC
5SL4606-8 — Protection
ParameterValue
Tripping characteristic (trip curve)D
Rated breaking capacity (Icn), per EN 6089810 kA
Rated breaking capacity, per IEC 60947-210 kA
Energy limitation class3
Overvoltage categoryIII
Pollution degree2
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingYes
Touch protectionYes
5SL4606-8 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SL4606-8 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)+55 °C, max. 95% humidity

Product details

Siemens SENTRON 5SL4606-8 — D-curve 6 A 4-pole MCB for motor and transformer circuits

The Siemens SENTRON 5SL4606-8 is a 4-pole (3P+N) miniature circuit breaker rated 6 A at 400 V AC with a D tripping characteristic and 10 kA breaking capacity per both EN 60898 and IEC 60947-2. Rated for ambient temperatures from -40 °C to +75 °C, it derates slightly at elevated panel temperatures: 5.76 A at 40 °C, 5.64 A at 45 °C, and 5.37 A at 55 °C.

Deployment context

The 76 mm depth (70 mm installation depth) fits typical enclosures with adequate gland-plate clearance. The neutral pole switches (neutral conductor switching function), making it suitable for single-phase or three-phase-plus-neutral circuits where the neutral must be disconnected with the phases.

Frequently asked questions

What is the breaking capacity of 5SL4606-8?

It is rated 10 kA per both EN 60898 and IEC 60947-2, so it will safely interrupt fault currents up to that level without upstream fuses needing to clear first.

Where can I buy 5SL4606-8?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Contact our desk for a current price and availability quote.

Will 5SL4606-8 drop into a panel specified for 5SL4106-7CC?

Both are 4-module DIN-rail MCBs from the same SENTRON 5SL family, so the physical footprint and mounting are identical. The key difference is the characteristic: 5SL4106-7CC is a C-curve (5–10× In), while the 5SL4606-8 is a D-curve (10–20× In). If the original design called for a C-curve, swapping to a D-curve may not trip fast enough on a short-circuit — check the load's inrush profile before substituting.

MPN
5SL4606-8