Siemens SENTRON miniature circuit breaker, 5SL4610-6, 4-pole (3P+N), B-characteristic, 10 A rated, 10 kA breaking capacity at 400 V AC, 4 MW units.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL4610-6 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityResidential buildings/infrastructure
5SL4610-6 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated voltage, AC (multi-phase)440 V
5SL4610-6 — Protection
ParameterValue
Tripping characteristic (trip curve)B
Energy limitation class3
Overvoltage categoryIII
Pollution degree2
Degree of protection (IP)IP20, with connected conductors
5SL4610-6 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SL4610-6 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
5SL4610-6 — Performance
ParameterValue
Power loss per pole, AC (hot state, at In)1.9 W

Product details

The Siemens SENTRON 5SL4610-6 is a 4-pole (3P+N) miniature circuit breaker with a B tripping characteristic, rated at 10 A and 400 V AC. It delivers a 10 kA breaking capacity per both EN 60898 and IEC 60947-2, so it clears faults up to that level without cascading upstream in residential or infrastructure distribution boards.

The B-curve (3–5× In) means this breaker trips fast on short-circuit but tolerates the modest inrush of resistive and lighting loads — it is not intended for motor starting, where a C or D curve would be needed to avoid nuisance trips. The 4-module-width (72 mm) body snaps onto a standard DIN rail and accepts auxiliary switches or shunt trips via the SENTRON accessory slot.

Frequently asked questions

What is the breaking capacity of 5SL4610-6?

10 kA per EN 60898 and IEC 60947-2 at 400 V AC.

What is the difference between 5SL4610-6 and 5SL4363-7?

The 5SL4363-7 is a 3-pole C-curve breaker rated 63 A, while the 5SL4610-6 is a 4-pole (3P+N) B-curve breaker rated 10 A. They share the same 76 mm depth and 90 mm height, but the 5SL4363-7 is 54 mm wide (3 MW) versus 72 mm (4 MW) for the 5SL4610-6, so they are not direct drop-in replacements without rewiring and panel space adjustment.

Where can I buy 5SL4610-6?

The 5SL4610-6 is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.

MPN