Skip to main content
Siemens 5SL4613-6 — 4-Pole MCB (DIN Rail)

Siemens 5SL4613-6 SENTRON MCB, 4-Pole B 13A 10kA

MPN5SL4613-6
Active

Siemens SENTRON 5SL4 series miniature circuit breaker, 4-pole (3P+N), B-curve, 13 A rated current, 10 kA breaking capacity per EN 60898, 400 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL4613-6 — Identification
ParameterValue
Type / order code5SL4
Brand nameSENTRON
Application suitabilityResidential buildings/infrastructure
5SL4613-6 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated current (In), AC13 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, DC (max.)60 V
Voltage typeAC
Rated frequency50 Hz
5SL4613-6 — Protection
ParameterValue
Tripping characteristic (trip curve)B
Rated breaking capacity (Icn), per EN 6089810 kA
Rated breaking capacity, per IEC 60947-210 kA
Overvoltage category3
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingYes
Touch protectionYes
5SL4613-6 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
SealableYes
5SL4613-6 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)+55 °C, max. 95% humidity
5SL4613-6 — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

The 5SL4613-6: The B-curve trips between 3 and 5 times rated current (39–65 A), which is the standard choice for resistive and general-purpose loads in residential and light commercial panels. The 4-pole (3P+N) design switches the neutral as well as the three phases, which is required in some regional wiring codes (e.g., UK, Australia) for final subcircuits.

Accepts solid or stranded conductors from 0.75 mm² up to 25 mm² — covers the full range for a 13 A circuit (typically 1.5–4 mm² final subcircuit, but the larger terminal capacity also handles incoming tails or busbar feed-through). Terminal torque specified at 2.5 to 3 N·m.

Frequently asked questions

Where can I buy the 5SL4613-6?

The 5SL4613-6 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of the 5SL4613-6?

The breaking capacity is 10 kA per both EN 60898 and IEC 60947-2, which is the standard rating for this class of MCB.

Does the 5SL4613-6 switch the neutral?

Yes, it is a 3P+N design with neutral conductor switching, so all four poles — three phases and neutral — are switched.

MPN
5SL4613-6