Skip to main content
Siemens 5SL4613-8 — Miniature Circuit Breakers (MCB)

Siemens 5SL4613-8 SENTRON MCB, D Curve, 4-Pole, 13 A, 10 kA

MPN5SL4613-8
Active

Siemens SENTRON 5SL4613-8 miniature circuit breaker, 4-pole (3P+N), D characteristic, 13 A at 30 °C, 10 kA breaking capacity per IEC 60898, 400 V AC, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SL4613-8 — Ratings
ParameterValue
Overvoltage categoryIII
5SL4613-8 — Mechanical
ParameterValue
Width72 mm
Height90 mm
Depth76 mm

Product details

The Siemens 5SL4613-8 is a SENTRON miniature circuit breaker (MCB) with a D tripping characteristic, four poles configured as 3P+N, and a rated current of 13 A at 30 °C. Breaking capacity is 10 kA per both IEC 60898 and IEC 60947-2, so it clears faults up to that level without upstream coordination issues in a residential or light-industrial distribution board. The 13 A rating derates with ambient temperature: 12.01 A at 40 °C, 11.44 A at 45 °C, and 10.35 A at 55 °C. The neutral conductor is switched (3P+N), which is required in some regional wiring codes to ensure the neutral is disconnected when the breaker is off. Touch protection is built in;

It occupies 4 modular width units (72 mm wide), with a depth of 76 mm and an installation depth of 70 mm. The 90 mm height keeps it within a standard consumer unit or sub-distribution board. Sealable design allows lockout-tagout in industrial or infrastructure panels. Rated for ambient temperatures from -40 °C to 75 °C, with up to 95% humidity at 55 °C. That range covers unheated electrical rooms in cold climates and warm enclosures near process equipment.

Frequently asked questions

How do I get current pricing and availability for 5SL4613-8?

Pricing and stock are confirmed at quote time. Submit an RFQ through this listing; the sourcing desk will return current availability and a firm price for your quantity.

Will 5SL4613-8 drop into a panel that was specified around 5SL4120-7CC without rewiring?

Both are 4-pole SENTRON MCBs with the same 72 mm width and DIN-rail mounting, so the mechanical fit is identical. The key difference is the tripping characteristic: the 5SL4120-7CC uses a B curve (for resistive/light loads), while the 5SL4613-8 uses a D curve (for high-inrush loads). If the panel was designed for a B-curve breaker, swapping to a D curve changes the protection coordination — verify the load type and upstream selectivity before substituting.

What compliance documentation does this brand provide for 5SL4613-8 (RoHS, REACH, UL, IEC)?

The breaker is designed to IEC 60898 and IEC 60947-2, with a 10 kA breaking capacity under both standards. The SENTRON series typically carries CE marking and RoHS compliance; specific UL or REACH documentation should be verified against the manufacturer's current declarations for this order code.

MPN
5SL4613-8