Siemens 5SL4615-7 — 4-Pole MCB (DIN Rail)

Siemens 5SL4615-7 SENTRON MCB, 400V 10kA, 3P+N, C-Curve, 1.6

MPN5SL4615-7
Active

Siemens SENTRON 5SL4615-7, miniature circuit breaker, 400 V AC, 10 kA, 3+N-pole, C characteristic, 1.6 A, 4 MW.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL4615-7 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityResidential buildings/infrastructure
5SL4615-7 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated voltage, AC (multi-phase)440 V
5SL4615-7 — Protection
ParameterValue
Tripping characteristic (trip curve)C
Energy limitation class3
Overvoltage categoryIII
Pollution degree2
Degree of protection (IP)IP20, with connected conductors
5SL4615-7 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SL4615-7 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
5SL4615-7 — Performance
ParameterValue
Power loss per pole, AC (hot state, at In)1.3 W

Product details

Siemens 5SL4615-7 SENTRON MCB — 1.6 A, C-Curve, 3P+N, 400 V, 10 kA

The Siemens 5SL4615-7 is a SENTRON miniature circuit breaker rated 400 V AC with a 10 kA breaking capacity certified to both EN 60898 and IEC 60947-2. It carries a C tripping characteristic at 1.6 A in a 3P+N (4-pole) configuration, occupying 4 modular width units on a DIN rail.

Mounting position is unrestricted — horizontal, vertical, or flat. The IP20 finger-safe enclosure applies only with connected conductors; terminals are live when open. The 3P+N design switches the neutral pole as well — not just a solid link. That matters for TN-S or TT systems where you need guaranteed isolation on all live conductors during maintenance. Sealable housing (provision for a lead seal or lockout) and halogen-free / silicon-free construction, so it's suitable for environments where outgassing from a fault could contaminate nearby electronics or where compliance with low-smoke material specs is required.

Overvoltage category III (fixed installation, not plug-in), pollution degree 2 (non-conductive dust only), energy limitation class 3 — all standard for a DIN-rail MCB in a distribution board.

Electrical and mechanical ratings

Rated for AC operation at 400/440 V, 50/60 Hz. DC rating is 72 V maximum — usable for DC branch circuits but only up to that voltage.