Siemens 5SL4615-8 — 4-Pole MCB (DIN Rail)

Siemens 5SL4615-8 SENTRON MCB, 4P D-curve 1.6 A 10 kA

MPN5SL4615-8
Active

Siemens SENTRON 5SL4 series, 5SL4615-8 miniature circuit breaker, 4-pole 3P+N, D characteristic, 1.6 A, 10 kA, 400 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL4615-8 — Identification
ParameterValue
Type / order code5SL4
Brand nameSENTRON
Application suitabilityResidential buildings/infrastructure
5SL4615-8 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated current (In), AC1.6 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, DC (max.)60 V
Voltage typeAC
Rated frequency50 Hz
5SL4615-8 — Protection
ParameterValue
Tripping characteristic (trip curve)D
Rated breaking capacity (Icn), per EN 6089810 kA
Rated breaking capacity, per IEC 60947-210 kA
Overvoltage category3
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingYes
Touch protectionYes
5SL4615-8 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
SealableYes
5SL4615-8 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)+55 °C, max. 95% humidity
5SL4615-8 — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

The Siemens 5SL4615-8 is a SENTRON 5SL4 miniature circuit breaker — 4-pole (3P+N), D tripping curve, rated 1.6 A at 400 V AC. The 10 kA breaking capacity (EN 60898 and IEC 60947-2) is the standard domestic and light-commercial fault level; it interrupts a bolted short-circuit up to 10 kA without welding the contacts or cascading the fault upstream. The neutral pole switches with the phases (3P+N), which is required in some regional wiring codes to ensure the neutral is not left floating when the breaker is off.

It occupies 4 width units (72 mm) and requires 70 mm installation depth behind the panel surface; the overall depth is 76 mm including the front projection. Terminal capacity accepts solid or stranded conductors from 0.75 to 25 mm². Ambient temperature range is -25 to +55 °C, with derating above 40 °C per the thermal curve. The breaker is sealable for tamper-proof installations. Mounting position is any orientation.

Frequently asked questions

What is the breaking capacity of 5SL4615-8?

10 kA rated value per both EN 60898 and IEC 60947-2. That is the standard fault-interruption rating for this class of MCB.

Where can I buy 5SL4615-8?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the D tripping curve used for?

The D characteristic (10–20× In) is designed for motor, transformer, or other inductive loads with high inrush current that would nuisance-trip a B or C curve breaker.

Will 5SL4615-8 drop into a panel specified around 5SL4120-7CC without rewiring?

Both are 4-pole 5SL4 series breakers on the same DIN-rail footprint with the same terminal range (0.75–25 mm²). The 5SL4615-8 is a 1.6 A D-curve; the 5SL4120-7CC is a different rating and curve. If the panel wiring and load match the 1.6 A D-curve, it fits mechanically without rewiring — but the protection settings differ, so verify the branch circuit's fault and overload requirements before swapping.