Siemens 5SL4616-6 — Miniature Circuit Breakers (MCB)

Siemens 5SL4616-6 SENTRON MCB, 3P+N, B-curve, 16 A, 400 V, 1

MPN5SL4616-6
Active

Siemens SENTRON 5SL4616-6 miniature circuit breaker, 3P+N, B-curve, 16 A, 400 V AC, 10 kA breaking capacity, 4 MW units, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SL4616-6 — Ratings
ParameterValue
Overvoltage categoryIII
5SL4616-6 — Mechanical
ParameterValue
Width72 mm
Height90 mm
Depth76 mm

Product details

The Siemens SENTRON 5SL4616-6 is a 3P+N miniature circuit breaker with a B-curve trip characteristic, rated 16 A at 400 V AC and a 10 kA breaking capacity per EN 60898 and IEC 60947-2. That 10 kA SCCR at 400 V means it safely interrupts fault currents up to that level without cascading upstream — a standard rating for residential and light commercial distribution boards. The 4-module-width (72 mm) body snaps onto DIN rail and accepts supplementary devices (auxiliary contacts, shunt trips, undervoltage releases) for downstream alarming or remote trip.

What the ratings mean for fit

B-curve trips between 3 and 5 times rated current (48–80 A magnetic release), so it's sized for resistive and general-purpose loads — lighting, small heaters, control transformers — not motor starting or high-inrush circuits where a C- or D-curve would be needed. The 3P+N design switches all three phases and switches the neutral, making it suitable for TN or TT systems where neutral isolation is required. The 10 kA breaking capacity at 400 V AC covers most utility-side fault levels in residential and infrastructure panels; if your service entrance has a higher prospective fault current, you'll need an upstream current-limiting device or a higher-rated breaker.

Panel integration

The 72 mm width (4 modular units) fits standard DIN-rail enclosures. IP20 with connected conductors means it's protected against finger contact but not moisture — install inside a panel with an IP54 or higher enclosure if washdown or outdoor exposure is expected. The sealable design allows padlocking the handle in the OFF position for lockout/tagout. Halogen-free and silicon-free construction matters for environments sensitive to corrosive off-gassing (data centers, clean rooms, marine).

Frequently asked questions

Where can I buy 5SL4616-6 and how do I get a price?

The 5SL4616-6 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

Will 5SL4616-6 drop into a panel that was specified around 5SL4363-7 without rewiring?

No — the 5SL4363-7 is a 3-pole (3P) C-curve breaker with a 72 mm width (3 MW units), while the 5SL4616-6 is a 4-pole (3P+N) B-curve breaker with a 72 mm width (4 MW units). The 5SL4616-6 is one modular unit wider and switches the neutral, so the panel's DIN-rail space and wiring scheme must accommodate the extra pole and width.

What compliance documentation does this brand provide for 5SL4616-6?

The 5SL4616-6 is rated per EN 60898 and IEC 60947-2 for breaking capacity. The SENTRON series typically carries CE, UKCA, and EAC markings; specific RoHS and REACH declarations are available from the manufacturer's documentation portal.

MPN
5SL4616-6