Siemens 5SL4616-8 — Miniature Circuit Breakers (MCB)

Siemens SENTRON 5SL4616-8 MCB, 4P D 16A 10kA 400V

MPN5SL4616-8
Active

Siemens SENTRON 5SL4616-8, 4-pole miniature circuit breaker, D-curve, 16 A, 10 kA breaking capacity at 400 V AC, 3+N-pole with neutral switching.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SL4616-8 — Ratings
ParameterValue
Overvoltage categoryIII
5SL4616-8 — Mechanical
ParameterValue
Width72 mm
Height90 mm
Depth76 mm

Product details

At 16 A, it's sized for moderate loads; the 4-pole version switches all three phases plus the switched neutral, so it's a single-device solution for three-phase final subcircuits.

For most commercial and light industrial panels fed by a transformer of 500 kVA or less, 10 kA at 400 V provides adequate SCCR headroom; above that, you'd step up to a 15 or 25 kA device. At elevated panel temperatures the breaker derates: 14.78 A at 40 °C, 14.08 A at 45 °C, and 12.74 A at 55 °C. If the panel runs hot — near a drive or transformer — factor the derated value into your load calculation. Voltage rating is 400 V AC line-to-line for multi-phase operation, with a maximum of 440 V AC. DC rating is 72 V maximum — not a DC-main breaker, but fine for control-circuit tap-offs.

The 4-module-width housing (72 mm wide) occupies four 18 mm slots. Mounting position is unrestricted — horizontal, vertical, or flat — so it fits tight enclosures without derating. Sealable, halogen-free, and silicon-free housing suits environments where outgassing or contamination is a concern.

The 5SL4616-8 is a standard catalog item in the Siemens SENTRON family, widely specified across European and Middle East infrastructure projects.

Frequently asked questions

What is the breaking capacity of 5SL4616-8?

10 kA per both IEC 60898 and IEC 60947-2 at 400 V AC.

Will 5SL4616-8 drop into a panel specified around 5SL6016-7KL without rewiring?

Both are 4-pole MCBs on 35 mm DIN rail, but the 5SL6016-7KL is a B-curve device; swapping to a D-curve changes the trip characteristic. Mechanically the footprint is the same 4-module width, so no rewiring of the busbar or terminals is needed — just verify the load inrush matches the D-curve.

Where can I buy 5SL4616-8?

Sourced and quoted to order through independent distribution channels. Submit an RFQ for current pricing and availability.