Siemens 5SL4620-6 — 4-Pole MCB (DIN Rail)

Siemens 5SL4620-6 SENTRON MCB, 3P+N, 20 A, B Curve, 10 kA

MPN5SL4620-6
Active

Siemens SENTRON 5SL4620-6, miniature circuit breaker, 3P+N, 20 A, B characteristic, 10 kA per EN 60898 / IEC 60947-2, 400 V AC, 4 MW.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL4620-6 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityResidential buildings/infrastructure
5SL4620-6 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated voltage, AC (multi-phase)440 V
5SL4620-6 — Protection
ParameterValue
Tripping characteristic (trip curve)B
Energy limitation class3
Overvoltage categoryIII
Pollution degree2
Degree of protection (IP)IP20, with connected conductors
5SL4620-6 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SL4620-6 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
5SL4620-6 — Performance
ParameterValue
Power loss per pole, AC (hot state, at In)2.5 W

Product details

The Siemens 5SL4620-6 is a SENTRON miniature circuit breaker rated 20 A with a B tripping characteristic, 3-pole plus neutral (3P+N), designed for 400 V AC multi-phase circuits. The B curve (3-5 In instantaneous trip) suits cable protection in residential and infrastructure runs where inrush from lighting or small transformers is modest. At 20 A it covers 2.5 mm² copper circuits in standard IEC installations. DC-rated maximum is 72 V, so it can also serve as a DC branch protector in control panels where the supply is rectified.

How the ratings govern real-world use

That means the same part can be specified for a house distribution board or a factory sub-panel without re-rating — a single BOM line covers both. Power loss is 2.5 W per pole in hot operating state at rated current. Not a frequent-switching device — this is set-and-forget overcurrent protection, not a contactor for motor cycling.

For BOM freeze or compliance documentation, the part carries the standard Siemens declarations (CE, UKCA, EAC) for the 5SL family. RoHS and REACH compliance is standard for current SENTRON production.

Frequently asked questions

Will the 5SL4620-6 drop into a panel specified for the 5SL4363-7?

Not without rewiring or a wider enclosure. The 5SL4620-6 is 72 mm wide (4 MW) versus 54 mm (3 MW) for the 5SL4363-7. The 5SL4620-6 also has 4 poles (3P+N) versus 3 poles on the 5SL4363-7, so it needs an additional neutral conductor connection and more DIN space. The depth and height are the same at 76 mm and 90 mm, so the panel depth is compatible.

What is the width of the 5SL4620-6?

72 mm, which corresponds to 4 modular width units (4 MW) on a standard DIN rail. The depth is 76 mm and the height is 90 mm.

MPN
5SL4620-6