Siemens 5SL4620-8 — 4-Pole MCB (DIN Rail)

Siemens SENTRON 5SL4620-8 MCB, 3P+N, D-curve, 20 A, 400 V, 1

MPN5SL4620-8
Active

Siemens SENTRON 5SL4620-8 miniature circuit breaker, 3P+N, D-curve, 20 A, 400 V AC, 10 kA breaking capacity, 4 modules wide.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL4620-8 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityResidential buildings/infrastructure
5SL4620-8 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated current (In), AC20 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, DC (max.)72 V
5SL4620-8 — Protection
ParameterValue
Tripping characteristic (trip curve)D
Energy limitation class3
Overvoltage categoryIII
Pollution degree2
Degree of protection (IP)IP20, with connected conductors
Touch protectionYes
5SL4620-8 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SL4620-8 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
5SL4620-8 — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

Siemens SENTRON 5SL4620-8 — D-curve MCB for high-inrush loads

The Siemens SENTRON 5SL4620-8 is a 3P+N miniature circuit breaker with a D tripping characteristic, rated 20 A at 400 V AC and a 10 kA breaking capacity per EN 60898. The 3P+N configuration includes a switched neutral, so it suits single-phase or three-phase circuits where neutral disconnection is required. Rated 20 A at 30 °C ambient; at 40 °C the continuous rating derates to 18.48 A, and at 55 °C to 15.92 A — factor this into panel thermal calculations if the breaker is in a warm enclosure.

IP20 with connected conductors; touch protection is built in, so no additional finger-safe covers are needed for the terminals. Sealable and halogen-free, silicon-free construction — suitable for installations with strict material-compatibility requirements (e.g., clean rooms, medical facilities). Degree of pollution 2, overvoltage category III, energy limitation class 3.

Frequently asked questions

What is the breaking capacity of the 5SL4620-8?

10 kA per EN 60898 and IEC 60947-2 at 400 V AC.

Where can I buy the 5SL4620-8?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the difference between the 5SL4620-8 and the 5SL4363-7?

The 5SL4620-8 is a 3P+N D-curve 20 A breaker; the 5SL4363-7 is a 3-pole C-curve 63 A breaker. The D-curve handles higher inrush (10–20× In) versus C-curve (5–10× In), and the 5SL4620-8 includes a switched neutral. They are not drop-in replacements — the pole count, rating, and characteristic differ.

MPN
5SL4620-8