Siemens 5SL4625-8 — 4-Pole MCB (DIN Rail)

Siemens SENTRON 5SL4625-8 MCB, 4P D 25A 10kA 400V

MPN5SL4625-8
Active

Siemens SENTRON 5SL4625-8 miniature circuit breaker, 3P+N (4-pole), D tripping characteristic, 25 A rated current, 400 V AC, 10 kA breaking capacity per EN 60898 / IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL4625-8 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityResidential buildings/infrastructure
5SL4625-8 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated voltage, AC (multi-phase)440 V
5SL4625-8 — Protection
ParameterValue
Tripping characteristic (trip curve)D
Energy limitation class3
Overvoltage categoryIII
Pollution degree2
Degree of protection (IP)IP20, with connected conductors
5SL4625-8 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SL4625-8 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
5SL4625-8 — Performance
ParameterValue
Power loss per pole, AC (hot state, at In)2.3 W

Product details

The Siemens SENTRON 5SL4625-8 is a 4-pole miniature circuit breaker (3P+N) with a D tripping characteristic, rated 25 A at 400 V AC. The 4-module-width (72 mm) body snaps onto standard DIN rail — no adapter needed for the neutral pole.

D-curve and breaking capacity

D-curve trips between 10× and 20× rated current, so this 25 A breaker holds through motor inrush and transformer energization without nuisance tripping. Rated impulse withstand voltage matches overvoltage category III, suitable for fixed-installation distribution boards.

Mounting position is unrestricted — horizontal or vertical in the enclosure. IP20 with connected conductors limits it to dry indoor panels; pollution degree 2 (non-conductive deposits only) matches typical residential or commercial distribution boards.

Frequently asked questions

What is 5SL4625-8's breaking capacity at 400 V?

The 5SL4625-8 is rated 10 kA at 400 V AC under both EN 60898 and IEC 60947-2, covering most residential and light commercial fault levels.

What is the difference between 5SL4625-8 and the 5SL4363-7?

The 5SL4363-7 is a 3-pole (3P) C-curve variant, while the 5SL4625-8 is 4-pole (3P+N) with a D-curve. The D-curve holds through higher inrush, making the 5SL4625-8 the correct choice for motor or transformer branch circuits. The 5SL4363-7 is 54 mm wide (3 modules); the 5SL4625-8 is 72 mm (4 modules) — the extra width is the switched neutral pole.

Where can I buy 5SL4625-8 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or price is published here.