Siemens 5SL6004-7 — 1-Pole MCB (DIN Rail)

Siemens 5SL6004-7 SENTRON MCB, 1P+N, C4, 6kA, 230V

MPN5SL6004-7
Active

Siemens SENTRON miniature circuit breaker, 5SL6004-7, 1P+N, C-characteristic, 6 kA breaking capacity per IEC/EN 60898-1, 230 V AC, 60 V DC, 1 modular width, DIN-rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6004-7 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Pole design1P+N
Application suitabilityResidential buildings/infrastructure
5SL6004-7 — Electrical & Protection
ParameterValue
Tripping characteristic classC
Energy limitation class3
Overvoltage categoryIII
5SL6004-7 — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodDIN rail
Combined terminal, topNo
Combined terminal, bottomNo
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SL6004-7 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree2
Halogen-freeYes
Silicone-freeYes

Product details

Rated 6 kA breaking capacity per IEC/EN 60898-1 at 230 V AC, it clears a fault up to that level without welding the contacts — enough for most final subcircuits in a TN or TT system. The 60 V DC rating covers control-voltage applications like relay coils or solenoid valves on a 48 V or 60 V DC bus.

Snaps onto a standard 35 mm DIN rail and occupies 1 modular width unit (18 mm,). The 76 mm depth and 70 mm installation depth mean it sits flush in a distribution board with standard 80 mm deep enclosures — no need to oversize the box. Mounting position is unrestricted, so it can be installed horizontally in a shallow panel if needed.

Designed to IEC/EN 60898-1 and GB/T10963.1. Halogen-free and silicon-free construction reduces corrosive off-gassing in a fire — relevant for installations in data centers or clean rooms. The part is sealable for anti-tamper applications. Vibration resistance per IEC 60068-2-6 is verified, and the mechanical service life is rated at 4 000 operating cycles typical.

Frequently asked questions

Who supplies 5SL6004-7 and how is it quoted for volume purchases?

The part is sourced through independent distribution and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time.

What is 5SL6004-7's listed depth (76 mm) on this component line?

The depth is 76 mm, with an installation depth of 70 mm.

What is 5SL6004-7's listed width (18 mm) on this component line?

The width is 18 mm, which corresponds to 1 modular width unit.

Will 5SL6004-7 drop into a panel that was specified around 5SL6120-7 without rewiring?

Both are 1-module-wide SENTRON MCBs on the same DIN-rail footprint, so the mechanical fit is identical. The difference is the current rating and possibly the breaking capacity — verify the branch circuit's load and fault level before substituting.

What compliance documentation does this brand provide for 5SL6004-7 (RoHS, REACH, UL, IEC)?

The part is designed to IEC/EN 60898-1 and GB/T10963.1. It is halogen-free and silicon-free. For RoHS/REACH declarations and any UL listing, request the manufacturer's compliance documents at quote time — they are not part of this listing.

MPN