Skip to main content
Siemens 5SL6010-7MC — 1-Pole MCB (DIN Rail)

Siemens 5SL6010-7MC SENTRON MCB, 1P+N, 230V, 1MW, Metering

MPN5SL6010-7MC
Active

Siemens SENTRON 5SL6010-7MC, miniature circuit breaker COM compact, 1P+N, 230 V AC, 1 modular width unit, with integrated ammeter, voltmeter, wattmeter, frequency meter, and reactive power meter.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6010-7MC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Pole design1P+N
Application suitabilityResidential buildings/infrastructure
5SL6010-7MC — Electrical & Protection
ParameterValue
Tripping characteristic classC
Energy limitation class3
Overvoltage categoryIII
5SL6010-7MC — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodDIN rail
Combined terminal, topNo
Combined terminal, bottomNo
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SL6010-7MC — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree2
Halogen-freeYes
Silicone-freeYes

Product details

What this 1P+N MCB does — and what the meters mean for a panel

What sets it apart from a plain MCB is the integrated metering: an ammeter, voltmeter, wattmeter, frequency meter, and reactive power meter are built into the same 18 mm footprint. That means one device handles both overcurrent protection and sub-metering for a single-phase circuit — no separate panel meter, no extra wiring, no lost DIN slots. Accuracy on the current and voltage measurements is 0.5 %, referenced to IEC61557-12, IEC62053-22, and IEC62053-23. The neutral pole is switched, so it disconnects both L and N when tripped. This is a current-production part — lifecycle stage is active, so it's still a standard catalog line from Siemens, not an end-of-life or NRND item.

Standards and compliance — what the approvals cover

Certified to IEC/EN 60898-1 and GB/T 10963.1. Energy limitation class is 3. Sealable design with separate L and N terminals.

Frequently asked questions

What is the width of 5SL6010-7MC?

18 mm, which is one modular width unit on a standard DIN-rail panel.

What compliance documentation is available for 5SL6010-7MC?

The breaker is certified to IEC/EN 60898-1 and GB/T 10963.1. The metering accuracy follows IEC 61557-12, IEC 62053-22, and IEC 62053-23. The housing is halogen-free and silicon-free.

MPN
5SL6010-7MC