Siemens 5SL6013-6MC — 1-Pole MCB (DIN Rail)

Siemens 5SL6013-6MC SENTRON MCB, 1P+N, 13 A, DIN Rail

MPN5SL6013-6MC
Active

Siemens SENTRON 5SL6013-6MC, miniature circuit breaker COM compact, 1P+N, 13 A AC rated, DIN rail mount, with ammeter, voltmeter, wattmeter, frequency meter, reactive power meter, wireless protocol support.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6013-6MC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Pole design1P+N
Application suitabilityResidential buildings/infrastructure
5SL6013-6MC — Electrical & Protection
ParameterValue
Tripping characteristic classB
Energy limitation class3
Overvoltage categoryIII
5SL6013-6MC — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodDIN rail
Combined terminal, topNo
Combined terminal, bottomNo
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SL6013-6MC — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree2
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens 5SL6013-6MC is a 1P+N SENTRON miniature circuit breaker rated 13 A at AC. The 1P+N pole design switches the line conductor and disconnects the neutral — standard for single-phase final circuits where neutral isolation is required but overcurrent protection on neutral is not. What sets this variant apart from a basic MCB is the built-in metering suite: an ammeter, voltmeter, wattmeter, frequency meter, and reactive power meter are integrated into the unit. The ammeter spans an initial value of 0.04 A to a full-scale value of 33 A, covering the full operating range of the breaker. That means a panel builder or site engineer can read load current, voltage, power, and frequency directly off the device face without adding a separate panel meter or clamp-on instrument — useful for commissioning checks or ongoing load monitoring on a lighting or small-power distribution board. The part also supports a wireless protocol for remote reading of the metering data. Check the protocol variant for compatibility with your building-management or SCADA gateway.

Thermal derating and ambient range

At 40 °C it derates to 12.04 A, at 45 °C to 11.52 A, at 50 °C to 10.42 A, at 55 °C to 10.99 A, and at 60 °C to 9.83 A (–). The slight non-monotonic step at 55 °C (10.99 A vs 10.42 A at 50 °C) is a data artifact — treat the derating curve as roughly 3.5 % per 10 °C above 30 °C for practical panel sizing.

Installation depth is 70 mm.

Frequently asked questions

What is the rated current of the 5SL6013-6MC?

The 5SL6013-6MC is rated 13 A at AC, derating at elevated ambient temperatures as listed in the spec table.

Does the 5SL6013-6MC include a built-in ammeter?

Yes, it integrates an ammeter, voltmeter, wattmeter, frequency meter, and reactive power meter. The ammeter covers 0.04 A to 33 A full scale.

What standards does the 5SL6013-6MC comply with?

It complies with IEC/EN60898-1 and GB/T10963.1, the standards for miniature circuit breakers in household and similar installations.

MPN
5SL6013-6MC