Siemens 5SL6016-7KL — 1-Pole MCB (DIN Rail)

Siemens 5SL6016-7KL SENTRON MCB, 16 A, C-Curve, 6 kA, 1P+N

MPN5SL6016-7KL
Active

Siemens SENTRON 5SL6016-7KL, miniature circuit breaker compact, 1P+N, 2 poles, C characteristic, 16 A at 230 V AC, 6 kA per EN 60898, 18 mm width, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6016-7KL — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles2
Pole design1P+N
Application suitabilityResidential buildings/infrastructure
5SL6016-7KL — Electrical & Protection
ParameterValue
Tripping characteristic classC
Rated value (EN 60898)6 kA
Energy limitation class3
Overvoltage categoryIII
5SL6016-7KL — Mounting & Connection
ParameterValue
Mounting positionany
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SL6016-7KL — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree2
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens 5SL6016-7KL is a SENTRON miniature circuit breaker (MCB) in a compact 1P+N design with two poles, switching both phase and neutral. Rated 16 A at 230 V AC with a C tripping characteristic, it provides 6 kA breaking capacity per EN 60898 — sufficient for residential and light commercial distribution boards where the prospective short-circuit current stays under that threshold. The 18 mm width (one modular unit) snaps onto standard DIN rail and accepts any mounting position, which simplifies panel layout.

What the ratings mean for fit

The C-curve (tripping characteristic class C) means the magnetic trip operates at 5 to 10 times rated current — typical for mixed resistive and moderate inductive loads like lighting circuits, small motors, and socket outlets. The 6 kA breaking capacity at 230 V AC per EN 60898 certifies it for use in final circuits where the fault level does not exceed that value. Overvoltage category III and pollution degree 2 suit fixed-installation distribution boards inside buildings. Thermal derating is published for ambient temperatures above 30 °C: 15.04 A at 40 °C, 14 A at 50 °C, and 12.89 A at 60 °C. If the panel runs hot — near a transformer or in a sealed enclosure — size the upstream protection against the derated figure, not the 30 °C nameplate.

Integration and compliance

The MCB mounts on DIN rail with a depth of 76 mm and an installation depth of 70 mm — verify enclosure depth clearance if the panel has a shallow backplate. The housing is halogen-free and silicon-free, which matters for clean-room or corrosive-environment installations. Touch protection is integrated, and the neutral conductor is switched (1P+N design). Sealable terminals allow lockout/tagout for maintenance isolation. Rated IP20 with connected conductors — suitable for dry indoor enclosures only, not washdown or outdoor exposure. Vibration resistance per IEC 60068-2-6 is confirmed, so it holds up in panels mounted on machinery or in transport applications.

Frequently asked questions

Where can I buy 5SL6016-7KL and how do I get a price?

The part is sourced to order against an RFQ through independent distribution. Submit a request for quote (RFQ) to confirm availability and current pricing — no stock or price figures are published here.

What is 5SL6016-7KL's listed depth (76 mm) on this component line?

The overall depth is 76 mm, with an installation depth of 70 mm. This is the dimension from the DIN-rail mounting surface to the front of the housing.

What is 5SL6016-7KL's listed width (18 mm) on this component line?

Width is 18 mm, which equals one modular unit (1 MW) on standard DIN rail. This allows 18 mm per pole spacing in the distribution board.

Will 5SL6016-7KL drop into a panel that was specified around 5SL6006-7 without rewiring?

Both share the same SENTRON compact form factor (18 mm width, 1P+N, C-curve, 6 kA). The 5SL6016-7KL is rated 16 A versus 6 A for the 5SL6006-7; if the circuit load exceeds 6 A, the 16 A unit fits mechanically but requires verifying that the downstream wiring and load are rated for the higher current. No rewiring of the busbar or DIN-rail mount is needed.

MPN
5SL6016-7KL