Skip to main content
Siemens 5SL6032-6 — 1-Pole MCB (DIN Rail)

Siemens 5SL6032-6 SENTRON MCB, B-Curve 1P+N, 6 kA

MPN5SL6032-6
Active

Siemens SENTRON 5SL6032-6, miniature circuit breaker compact, B-curve, 1P+N, 6 kA breaking capacity per IEC/EN 60898-1, 18 mm wide, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6032-6 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Pole design1P+N
Application suitabilityResidential buildings/infrastructure
5SL6032-6 — Electrical & Protection
ParameterValue
Tripping characteristic classB
Energy limitation class3
Overvoltage categoryIII
5SL6032-6 — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodDIN rail
Combined terminal, topNo
Combined terminal, bottomNo
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SL6032-6 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree2
Halogen-freeYes
Silicone-freeYes

Product details

What it is and where it fits

The Siemens 5SL6032-6 is a SENTRON miniature circuit breaker (MCB) in a compact 1P+N design — it switches both the phase and the neutral, with the neutral pole following the phase. It is a B-curve device with 6 kA breaking capacity at 230 V AC per IEC/EN 60898-1. The 18 mm width (one modular unit) and DIN-rail fastening mean it snaps into any standard distribution board or sub-panel without eating extra space. Mounting position is unrestricted, and the IP20 rating with connected conductors is typical for enclosed panel use — no special sealing needed inside a cabinet.

What the ratings mean for the panel builder

The 76 mm depth and 70 mm installation depth are key for shallow enclosures. The 18 mm width per pole (1 MWU) allows high rail density. The B-curve characteristic means the magnetic trip threshold is lower than a C-curve, so it's more sensitive to short-circuit faults but may nuisance-trip on motor or transformer inrush. That's by design for the intended residential/infrastructure duty. The neutral conductor is switched (1P+N), which is required in some national wiring regulations for single-phase final circuits — verify your local code. Operating temperature range of -25 °C to 45 °C at up to 85% relative humidity, derating to 43% rF above 45 °C up to 60 °C. That covers most indoor panel environments; if the breaker lives in an unconditioned outdoor cabinet in a hot climate, check the derating curve for the actual ambient. Power loss is 2.8 W per pole at rated current in hot operating state — negligible for thermal budgeting in a populated board, but worth noting if you're packing high-density MCBs in a sealed enclosure with no forced ventilation.

Compliance and documentation

Designed and tested to IEC/EN 60898-1 and GB/T 10963.1 (Chinese national standard). Overvoltage category III, pollution degree 2 — standard for fixed-installation distribution boards. The product is halogen-free and silicon-free, which matters for environments where outgassing from a fault could contaminate sensitive equipment or where silicone contamination affects downstream processes. Vibration resistance per IEC 60068-2-6 is confirmed, and the mechanical service life is rated at 10,000 operating cycles typical. Sealable design allows the installer to lock the toggle position — useful for tamper-proofing in public-access panels.

Frequently asked questions

What compliance documentation does Siemens provide for 5SL6032-6?

The breaker is designed to IEC/EN 60898-1 and GB/T 10963.1. It is halogen-free and silicon-free. For specific RoHS, REACH, or UL documentation, the manufacturer's declaration or certificate of conformity should be requested at quote time — those are not pre-loaded on this listing.

MPN
5SL6032-6