Skip to main content
Siemens 5SL6101-7MB — 1-Pole MCB (DIN Rail)

Siemens 5SL6101-7MB SENTRON MCB, 1A C-Curve, 1-Pole, 6kA

MPN5SL6101-7MB
Active

Siemens SENTRON miniature circuit breaker, 5SL6101-7MB, 1-pole, C-curve, 1 A, 6 kA breaking capacity per IEC 60898 and IEC 60947-2, 230/400 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SL6101-7MB — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Pole design1P
Application suitabilityResidential buildings/infrastructure
5SL6101-7MB — Electrical & Protection
ParameterValue
Tripping characteristic classC
Energy limitation class3
Overvoltage categoryIII
5SL6101-7MB — Mounting & Connection
ParameterValue
Mounting positionany
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SL6101-7MB — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree2
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens SENTRON 5SL6101-7MB is a 1-pole miniature circuit breaker rated 1 A with a C-trip curve and a 6 kA breaking capacity certified to both EN 60898 and IEC 60947-2. This dual-standard rating means the part is accepted for residential and infrastructure branch-circuit protection (EN 60898) and also meets the industrial coordination requirements of IEC 60947-2 for panel builders who need documented SCCR compliance.

Compared to the 5SL6120-7 (20 A, same 1-pole C-curve, same 6 kA rating), the 5SL6101-7MB shares the identical 18 mm width and 76 mm depth, so it drops into the same DIN-rail panel layout without rewiring. The difference is purely the current rating: 1 A versus 20 A, which governs the load it protects. The 5SL6101-7MB also carries a higher mechanical service life of 20 000 operating cycles typical versus 10 000 on the 5SL6120-7, reflecting the lower thermal stress at its rated current.

Single modular width (18 mm) means it occupies one slot.

Frequently asked questions

What is the breaking capacity of the 5SL6101-7MB?

The breaking capacity is 6 kA at 230/400 V AC, certified to both EN 60898 and IEC 60947-2. This dual certification covers both residential and industrial coordination requirements.

Will the 5SL6101-7MB fit in a panel designed for the 5SL6120-7?

Yes, the 5SL6101-7MB shares the same 18 mm width, 76 mm depth, and 90 mm height as the 5SL6120-7, so it drops into the same DIN-rail panel layout without any rewiring or mechanical modification.

How do I get current pricing and availability for the 5SL6101-7MB?

Pricing and availability are confirmed at quote time. Submit an RFQ through this listing; the part is sourced to order through independent distribution channels.

MPN
5SL6101-7MB