Skip to main content
Siemens 5SL6101-7RC — 1-Pole MCB (DIN Rail)

Siemens 5SL6101-7RC SENTRON MCB, 1 A, 1-Pole, C-Curve, 7.5 k

MPN5SL6101-7RC
Active

Siemens SENTRON 5SL6101-7RC miniature circuit breaker, 1 A, 1-pole, C characteristic, 7.5 kA breaking capacity per EN 60898, 1 MW unit, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SL6101-7RC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Pole design1P
Application suitabilityResidential buildings/infrastructure
5SL6101-7RC — Electrical & Protection
ParameterValue
Tripping characteristic classC
Energy limitation classNo
Overvoltage categoryIII
5SL6101-7RC — Mounting & Connection
ParameterValue
Mounting positionany
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SL6101-7RC — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree2
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens 5SL6101-7RC is a 1 A, 1-pole SENTRON miniature circuit breaker with a C tripping characteristic and a 7.5 kA breaking capacity rated per EN 60898 at 415 V AC. It occupies a single modular width (18 mm) on the DIN rail, making it a tight fit for residential or light commercial sub-distribution boards where branch-circuit overcurrent protection is needed for lighting or small loads.

What the ratings mean for fit

The C-curve (magnetic trip between 5× and 10× In) is standard for moderate inrush loads like small transformers, fluorescent ballasts, or motorized valves — not for high-surge motor starts (use D-curve) or purely resistive circuits (B-curve works). At 1 A rated current, this breaker protects a circuit drawing up to 1 A continuous; the 7.5 kA breaking capacity per EN 60898 means it can safely interrupt a fault current of up to 7.5 kA at 415 V AC without welding contacts or cascading damage upstream. That's adequate for most residential and light commercial service entrances where the prospective short-circuit current stays under 7.5 kA.

Panel integration and environment

Snaps onto a 35 mm DIN rail (EN 60715) in any mounting position. At 18 mm wide (1 MW), it leaves room for adjacent breakers or accessories. The IP20 rating with connected conductors means it's protected against finger contact but not washdown — keep it inside a closed panel or enclosure. Rated for ambient temperatures from -40 °C to 75 °C, so it handles unconditioned electrical rooms or outdoor enclosures in most climates. The 70 mm installation depth fits standard 100 mm deep consumer units.

Frequently asked questions

Where can I buy the 5SL6101-7RC?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Will the 5SL6101-7RC drop into a panel built for the 5SL4363-7?

No — the 5SL4363-7 is a 3-pole, 54 mm wide breaker, while the 5SL6101-7RC is a 1-pole, 18 mm wide unit. They share the same 76 mm depth and 90 mm height, so the physical envelope differs only in width and pole count. You would need to re-terminate the circuit and adjust the DIN-rail fill.

What compliance documentation does Siemens provide for the 5SL6101-7RC?

The part carries CE marking per the Low Voltage Directive and is designed to EN 60898. It is halogen-free and silicon-free. Specific declarations (RoHS, REACH, UL) should be requested with the RFQ.

MPN
5SL6101-7RC