Siemens 5SL6102-6 SENTRON MCB, 1P B-curve 2A 6kA

MPN5SL6102-6
Active

Siemens SENTRON 5SL6102-6 miniature circuit breaker, 1-pole, B-curve, 2 A, 6 kA breaking capacity per EN 60898 / IEC 60947-2, 230/400 V AC, 1 MW unit.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6102-6 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Pole design1P
Application suitabilityResidential buildings/infrastructure
5SL6102-6 — Electrical & Protection
ParameterValue
Tripping characteristic classB
Energy limitation class3
Overvoltage categoryIII
5SL6102-6 — Mounting & Connection
ParameterValue
Mounting positionany
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SL6102-6 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree2
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens 5SL6102-6 is a SENTRON miniature circuit breaker — 1-pole, B-curve, rated 2 A with a 6 kA breaking capacity per both EN 60898 and IEC 60947-2.

Mounting position is unrestricted; you can lay it sideways or upside-down in a tight gland plate layout. The IP20 rating applies with conductors connected, meaning the busbar stabs and terminals are touch-safe once wired. Sealable with a lead seal if the panel spec requires tamper evidence.

B-curve trip and load suitability

B-curve trips between 3 and 5 times rated current — so the 2 A version holds through a 6–10 A inrush but clears quickly on a hard short. That makes it a natural fit for resistive loads and general-purpose lighting circuits where you don't expect motor-starting surges.

Compared to the 5SL4363-7, which is a 3-pole C-curve 10 kA breaker in a 54 mm-wide (3 MW) package, the 5SL6102-6 is a single-pole B-curve 6 kA unit at 18 mm wide. The 5SL4363-7 handles higher fault currents and three-phase circuits, but it won't drop into a 1 MW slot — you'd need three times the DIN rail width and a different busbar arrangement. The 5SL6132-6MB is the same 1-pole B-curve 6 kA form factor but rated 32 A; the 5SL6102-6 is the 2 A variant for lower-current branch circuits.

Frequently asked questions

Where can I buy 5SL6102-6 and get a price?

The 5SL6102-6 is sourced to order against an RFQ through independent distribution. Submit a request for a firm quote — availability and current pricing are confirmed at quote time.

What is the breaking capacity of 5SL6102-6?

The 5SL6102-6 is rated 6 kA per both EN 60898 and IEC 60947-2, meaning it safely interrupts faults up to 6,000 A.

Will 5SL6102-6 fit in a panel designed for 5SL4363-7?

No — the 5SL4363-7 is a 3-pole breaker occupying 54 mm (3 MW) of DIN rail, while the 5SL6102-6 is a single-pole unit at 18 mm (1 MW). The busbar arrangement and wiring plan would need to change.

MPN