Specifications

5SL6106-6RC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Pole design1P
Application suitabilityResidential buildings/infrastructure
5SL6106-6RC — Electrical & Protection
ParameterValue
Tripping characteristic classB
Rated value (EN 60898)7.5 kA
Energy limitation classNo
Overvoltage categoryIII
5SL6106-6RC — Mounting & Connection
ParameterValue
Mounting positionany
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SL6106-6RC — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree2
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens SENTRON 5SL6106-6RC is a 1-pole miniature circuit breaker rated 6 A with a B tripping characteristic and a 7.5 kA breaking capacity per EN 60898.

The B characteristic means the breaker trips between 3 and 5 times rated current — 18 A to 30 A — which suits resistive and lighting loads with low inrush. The 7.5 kA breaking capacity (per EN 60898) tells you it can safely interrupt a fault current up to that level at the rated voltage; for most residential panels with a typical prospective short-circuit current under 6 kA, this provides headroom. The 6 A rating at 30 °C ambient is the continuous current the breaker carries without tripping; derate if the panel ambient exceeds 30 °C. Rated for AC operation up to 415 V (single-phase 250 V, multi-phase 440 V max) and DC up to 72 V.

One modular width (18 mm) means it occupies a single slot in the distribution board. Mounting position is any — vertical, horizontal, or upside-down — which simplifies panel layout. Sealable terminals allow the installer to lock the cover after commissioning, preventing tampering.

Frequently asked questions

What is the breaking capacity of the 5SL6106-6RC?

The 5SL6106-6RC has a breaking capacity of 7.5 kA per EN 60898 at the rated AC voltage. This is sufficient for most residential and light commercial distribution boards where the prospective short-circuit current is typically lower.

Will the 5SL6106-6RC drop into a panel specified around the 5SL3120-6MB?

Both breakers share the same SENTRON 5SL family footprint — same depth (76 mm), width (18 mm), height (90 mm), and DIN-rail mounting. The 5SL6106-6RC is rated 6 A with a 7.5 kA breaking capacity, while the 5SL3120-6MB is a 20 A unit with a 4.5 kA breaking capacity. If the panel was designed for the 5SL3120-6MB, the 5SL6106-6RC will physically fit without rewiring, but the current rating and breaking capacity differ — verify the circuit's load and fault level before substituting.

Where can I buy the 5SL6106-6RC?

The 5SL6106-6RC is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

MPN
5SL6106-6RC