Siemens 5SL6120-7BB — 1-Pole MCB (DIN Rail)

Siemens 5SL6120-7BB SENTRON MCB, 1P C-curve 20 A, 6 kA

MPN5SL6120-7BB

Siemens SENTRON 5SL6120-7BB, 1-pole miniature circuit breaker, C characteristic, 20 A rated, 6 kA breaking capacity per EN 60898, 250/440 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6120-7BB — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Application suitabilityResidential buildings/infrastructure
5SL6120-7BB — Electrical & Protection
ParameterValue
Tripping characteristic classC
Rated value (EN 60898)6 kA
Energy limitation class3
Overvoltage categoryIII
5SL6120-7BB — Mounting & Connection
ParameterValue
Mounting positionany
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SL6120-7BB — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree2
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens 5SL6120-7BB is a SENTRON miniature circuit breaker (MCB) — a 1-pole, C-curve device rated 20 A at 30 °C, with a 6 kA breaking capacity certified to both EN 60898 and IEC 60947-2. Single-phase operation is rated 250 V AC; multi-phase (line-to-line) goes up to 440 V AC. That covers standard North American 120/240 V split-phase panels and European 230/400 V three-phase distribution boards.

Where it fits — panel and environment

Width is 18 mm — one modular unit on a standard DIN rail. Depth is 76 mm (70 mm installation depth), so it sits flush in a shallow enclosure without crowding the wiring gutter. Mounting position is unrestricted; you can lay the panel on its back for commissioning without worrying about orientation. Pollution degree 2 (normal, non-conductive) and overvoltage category III (distribution-level) are standard for residential and light commercial infrastructure.

Thermal derating — the real-world current

At 40 °C it derates to 18.48 A, at 45 °C to 17.6 A, and at 55 °C to 15.92 A.

Frequently asked questions

What is the breaking capacity of the 5SL6120-7BB?

Rated 6 kA per both EN 60898 and IEC 60947-2, which covers most residential and light commercial fault levels.

Will the 5SL6120-7BB drop into a panel specified for a 5SL6132-6MB?

Both are 1-pole SENTRON MCBs on an 18 mm footprint, so the physical fit is the same. The difference is rating: the 5SL6120-7BB is a 20 A C-curve, while the 5SL6132-6MB is a 32 A B-curve. No rewiring needed if the load current and trip characteristic match the circuit design.

Where can I buy the 5SL6120-7BB?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an inquiry for a firm quote.

MPN
5SL6120-7BB