Siemens 5SL6125-6MB — 1-Pole MCB (DIN Rail)

Siemens 5SL6125-6MB SENTRON MCB, 1P B 25A 6kA

MPN5SL6125-6MB
Active

Siemens SENTRON 5SL6125-6MB miniature circuit breaker, 1-pole, B-curve, 25 A rated current, 6 kA breaking capacity per EN 60898, 230/400 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6125-6MB — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Pole design1P
Application suitabilityResidential buildings/infrastructure
5SL6125-6MB — Electrical & Protection
ParameterValue
Tripping characteristic classB
Rated value (EN 60898)6 kA
Energy limitation class3
Overvoltage categoryIII
5SL6125-6MB — Mounting & Connection
ParameterValue
Mounting positionany
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SL6125-6MB — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree2
Halogen-freeYes
Silicone-freeYes

Product details

Siemens 5SL6125-6MB — SENTRON 1-pole B-curve MCB, 25 A, 6 kA

The Siemens 5SL6125-6MB is a SENTRON miniature circuit breaker, 1-pole, with a B tripping characteristic, rated 25 A at 30 °C and 230/400 V AC. Its 6 kA breaking capacity per EN 60898 covers most residential and light commercial branch circuits — think lighting, socket outlets, and general-purpose loads where inrush is modest. The B-curve trips between 3 and 5 times rated current, so it's a good fit for resistive and small inductive loads, but not for motor starts or transformer inrush where a C or D curve would be needed. At 18 mm wide (1 modular unit), it snaps onto standard DIN rail and occupies one slot in a distribution board. Depth is 76 mm, installation depth 70 mm — check your enclosure depth if you're retrofitting into a shallow panel. Rated for overvoltage category III and pollution degree 2, which is standard for fixed-installation downstream of the utility meter.

What the ratings mean for fit

The 25 A rating at 30 °C is the continuous current the breaker carries without tripping in a 30 °C ambient. If your panel runs hotter, you'll need to derate — the 25 A figure at 30 °C is the baseline. The 6 kA breaking capacity per EN 60898 means it can safely interrupt a fault current up to 6 kA at 230/400 V AC. That's adequate for most residential and light commercial service entrances where the prospective short-circuit current is under 6 kA. If your installation has a higher fault level (e.g., near a large transformer), you'd need a breaker with a higher breaking capacity, like the 10 kA or 15 kA variants in the 5SL series. The B-curve (3-5× In) is the standard choice for general-purpose circuits with resistive or small inductive loads. It's not intended for motor circuits or high-inrush loads — those would need a C or D curve to avoid nuisance tripping on startup. The 1-pole design switches the line conductor only; neutral is not switched. For single-phase circuits, the rated voltage is 250 V AC; for multi-phase (e.g., 2- or 3-pole ganged) it's 440 V AC maximum.

Mechanical and environmental

Rated for 10,000 mechanical switching cycles typical. Ambient temperature range -40 °C to 75 °C, which covers most indoor and sheltered outdoor installations. IP20 with connected conductors — not suitable for wet or dusty environments without additional enclosure. Halogen-free and silicon-free, which matters for installations in sensitive environments like hospitals or data centers where off-gassing from a fault could damage equipment.

Frequently asked questions

Where can I buy 5SL6125-6MB and get a price?

The 5SL6125-6MB is sourced to order through our independent distribution channel. Submit an RFQ and we'll confirm current availability and pricing at quote time — no stock or price figures are published here.

What is the closest functional second-source for 5SL6125-6MB?

The closest functional peer within the same series is the 5SL6132-6MB, which is identical in form factor (1-pole, B-curve, 6 kA, same dimensions) but rated 32 A instead of 25 A. It drops into the same panel footprint without rewiring — just swap the breaker if the load requires the higher rating. For a direct 25 A replacement, stick with the 5SL6125-6MB.

Will 5SL6125-6MB drop into a panel specified for 5SL6132-6MB?

Yes, the 5SL6125-6MB shares the same physical footprint (18 mm width, 76 mm depth, 90 mm height) and DIN-rail mounting as the 5SL6132-6MB. It will fit without any panel modification. The only difference is the current rating — 25 A vs 32 A — so verify the load before swapping.

What compliance documentation does Siemens provide for 5SL6125-6MB?

The 5SL6125-6MB is designed and tested per EN 60898 (breaking capacity 6 kA) and IEC 60947-2 (overvoltage category III, pollution degree 2). It carries CE marking for the European market. Siemens typically provides a declaration of conformity and technical data sheet upon request. Specific RoHS/REACH/UL documentation should be confirmed at order time.

MPN