Siemens 5SL6150-7 — 1-Pole MCB (DIN Rail)

Siemens 5SL6150-7 SENTRON MCB, 1P C 50A 6kA

MPN5SL6150-7
Active

Siemens SENTRON 5SL6150-7, 1-pole miniature circuit breaker, C-curve, 50 A rated current, 6 kA breaking capacity per EN 60898 and IEC 60947-2, 230/400 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SL6150-7 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Pole design1P
Application suitabilityResidential buildings/infrastructure
5SL6150-7 — Electrical & Protection
ParameterValue
Tripping characteristic classC
Energy limitation class3
Overvoltage categoryIII
5SL6150-7 — Mounting & Connection
ParameterValue
Mounting positionany
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SL6150-7 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree2
Halogen-freeYes
Silicone-freeYes

Product details

Siemens 5SL6150-7 SENTRON MCB — 1-pole C-curve 50 A, 6 kA

The Siemens 5SL6150-7 is a 1-pole SENTRON miniature circuit breaker with a C tripping characteristic, rated 50 A at 230/400 V AC.

At 50 A it handles a 11.5 kW resistive load on a single phase (230 V) or a 34.5 kW three-phase load (400 V) before the thermal-magnetic trip engages. Single-pole construction means it switches only the phase conductor — use it in single-phase branch circuits or as one pole of a multi-pole assembly. The 76 mm depth and 90 mm height are standard SENTRON dimensions, so it aligns with busbar systems and enclosure cutouts across the 5SL family. Rated for overvoltage category III (fixed installation) and pollution degree 2, it is suited for clean indoor environments typical of residential and infrastructure panels.

A single modular width (18 mm) means 18 breakers fit per meter of DIN rail. The unit is sealable — a lead seal can be fitted through the front cover to prevent tampering after commissioning.

Frequently asked questions

Where can I buy the 5SL6150-7 and how do I get a price?

The 5SL6150-7 is sourced to order through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time, not a stock promise.

What is the difference between the 5SL6150-7 and the 5SL4363-7?

The 5SL4363-7 is a 3-pole version rated 10 kA breaking capacity (vs. 1-pole, 6 kA on the 5SL6150-7). It occupies 3 modular widths (54 mm) instead of 1 (18 mm). Both share the same C-curve, 400 V AC rating, and SENTRON form factor — but the 5SL4363-7 is for three-phase branch circuits or higher fault-current locations. It will not drop into a single-pole slot without rewiring the busbar.