Skip to main content
Siemens 5SL6204-7RC — 2-Pole MCB (DIN Rail)

Siemens 5SL6204-7RC SENTRON MCB, 4A 2-pole C, 7.5 kA

MPN5SL6204-7RC
Active

Siemens SENTRON 5SL6204-7RC, miniature circuit breaker, 4 A, 2-pole, C characteristic, 7.5 kA breaking capacity per EN 60898 at 415 V AC, 2 modular width units (36 mm).

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6204-7RC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentResidential buildings/infrastructure
5SL6204-7RC — Electrical
ParameterValue
Number of poles2
Supply voltage at AC rated value415 V
5SL6204-7RC — Protection
ParameterValue
Tripping characteristic classC
Overvoltage categoryIII
5SL6204-7RC — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SL6204-7RC — Environmental
ParameterValue
Pollution degree2
5SL6204-7RC — Specifications
ParameterValue
According to EN 60898 rated value7.5 kA
With single-phase operation at AC rated value250 V
Energy Limitation ClassNo

Product details

Siemens 5SL6204-7RC — 4 A, 2-pole, C-curve MCB

The Siemens 5SL6204-7RC is a SENTRON miniature circuit breaker rated 4 A with a C tripping characteristic, 2-pole design, and a 7.5 kA breaking capacity per EN 60898 at 415 V AC.

The 7.5 kA rating per EN 60898 at 415 V AC defines the maximum prospective fault current this MCB can safely interrupt under standard conditions. In a panel with mixed loads, the C-curve avoids nuisance trips from brief starting currents that a B-curve would catch. At 1.3 W power loss per pole in hot operating state at rated current, the thermal contribution to the enclosure is modest — two poles dissipate 2.6 W total. In a densely packed DIN-rail enclosure with multiple MCBs, this keeps the internal temperature rise manageable without forced ventilation.

DIN-rail fit and modular accessories

Supplementary devices such as shunt trips, undervoltage releases, or auxiliary contacts can be installed on the 5SL6204-7RC (Product Extension Installable Supplementary Devices = Yes). This allows remote tripping or status feedback without replacing the base MCB.

The SENTRON 5SL series is a current-generation platform from Siemens. No successor order code has been announced, and the part carries the full complement of IEC/EN approvals typical for European-distribution-board components.

Frequently asked questions

What is the breaking capacity of the 5SL6204-7RC?

The 5SL6204-7RC has a 7.5 kA breaking capacity per EN 60898 at 415 V AC. This is the maximum fault current it can safely interrupt under standard test conditions.

What is the width and depth of the 5SL6204-7RC?

The 5SL6204-7RC has a width of 36 mm (2 modular width units) and a depth of 76 mm. Installation depth on the DIN rail is 70 mm.

Where can I buy the 5SL6204-7RC?

The 5SL6204-7RC is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Will the 5SL6204-7RC fit in a panel designed for the 5SL4363-7?

The 5SL6204-7RC is 2-pole (36 mm wide), while the 5SL4363-7 is 3-pole (54 mm wide). Both share the same 76 mm depth and 70 mm installation depth, so the 5SL6204-7RC will fit the same DIN-rail mounting but occupies 1 fewer modular unit. No rewiring is needed if the circuit is 2-pole; the 3-pole version would require a different circuit configuration.

MPN
5SL6204-7RC