Siemens 5SL6205-7CC — 2-Pole MCB (DIN Rail)

Siemens 5SL6205-7CC SENTRON MCB, 2-pole C 0.5A 6kA

MPN5SL6205-7CC
Active

Siemens SENTRON 5SL6205-7CC, miniature circuit breaker, 2-pole, C characteristic, 0.5 A, 400 V AC, 6 kA breaking capacity per EN 60898, 2 MW units.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

5SL6205-7CC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentResidential buildings/infrastructure

Electrical

5SL6205-7CC — Electrical
ParameterValue
Number of poles2
Supply voltage at AC rated value400 V

Protection

5SL6205-7CC — Protection
ParameterValue
Tripping characteristic classC
Overvoltage categoryIII

Mechanical

5SL6205-7CC — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors

Environmental

5SL6205-7CC — Environmental
ParameterValue
Pollution degree2

Specifications

5SL6205-7CC — Specifications
ParameterValue
According to EN 60898 rated value6 kA
Energy Limitation Class3

Product details

The Siemens 5SL6205-7CC is a SENTRON miniature circuit breaker (MCB) with a 2-pole design, C tripping characteristic, and a rated current of 0.5 A at 400 V AC. Its 6 kA breaking capacity is certified per EN 60898, making it suitable for residential and infrastructure branch-circuit protection where short-circuit levels stay within that threshold.

What the ratings mean for fit

The C-curve (tripping characteristic class C) means the magnetic trip operates at 5 to 10 times rated current — appropriate for circuits with moderate inrush, such as lighting banks or small transformers. At 0.5 A, this is a low-current branch breaker, not a feeder or motor-circuit device. The 6 kA breaking capacity per EN 60898 defines the maximum prospective fault current the breaker can safely interrupt at 400 V AC. For installations where the available fault current exceeds 6 kA, a current-limiting upstream device or a higher-rated breaker (e.g., 10 kA per IEC 60947-2) would be required. Rated for overvoltage category III and pollution degree 2, this MCB is designed for fixed-installation distribution boards within a building's main or sub-distribution — not for outdoor or wet-location panels without additional enclosure protection.

Panel integration and mounting

Occupies 2 modular width units (36 mm) on a DIN rail. Installation depth is 70 mm; overall depth including terminals is 76 mm. Mounting position is unrestricted — the breaker operates correctly in any orientation. IP20 rating applies only with connected conductors — the terminals are finger-safe when wired, but the breaker itself is not sealed against dust ingress or moisture. Sealable design allows locking in the OFF position for lockout/tagout compliance. Supplementary devices (auxiliary switches, shunt trips, alarm contacts) can be installed on the side, per the product extension feature. Power loss is 0.9 W per pole at rated current in hot operating state — negligible for thermal budgeting in a populated distribution board.

Frequently asked questions

Will 5SL6205-7CC fit in a panel designed for 5SL4363-7?

The 5SL6205-7CC is 2 MW wide (36 mm) versus the 5SL4363-7 at 3 MW (54 mm). It will physically snap onto the same DIN rail but occupies one fewer module width. Rewiring is not required if the circuit is 2-pole; the 5SL4363-7 is a 3-pole breaker, so the pole count differs.