Skip to main content
Siemens 5SL6206-7 — 2-Pole MCB (DIN Rail)

Siemens 5SL6206-7 SENTRON MCB, 2P C 6A 6kA, 400V AC

MPN5SL6206-7
Active

Siemens SENTRON 5SL6206-7 miniature circuit breaker, 2-pole, C-curve, 6 A, 6 kA breaking capacity per EN 60898 / IEC 60947-2, 400 V AC, 50/60 Hz.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6206-7 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentResidential buildings/infrastructure
5SL6206-7 — Electrical
ParameterValue
Number of poles2
Supply voltage at AC rated value400 V
5SL6206-7 — Protection
ParameterValue
Tripping characteristic classC
Overvoltage categoryIII
5SL6206-7 — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SL6206-7 — Environmental
ParameterValue
Pollution degree2
5SL6206-7 — Specifications
ParameterValue
According to EN 60898 rated value6 kA
Energy Limitation Class3

Product details

Siemens SENTRON 5SL6206-7 — 2-pole C-curve MCB, 6 A, 6 kA

The Siemens SENTRON 5SL6206-7 is a 2-pole miniature circuit breaker rated 6 A with a C tripping characteristic, designed for 400 V AC (440 V max multi-phase) at 50/60 Hz.

Integration and ratings

The 2-pole design switches both phase and neutral (or two phases) in a single module width of 36 mm. Sealable per the datasheet, which allows panel builders to lock the toggle position after commissioning. Power loss per pole at rated current in hot operating state is 0.7 W, so the total thermal dissipation for a 2-pole unit is 1.4 W — negligible for enclosure heat budgeting but worth noting in a densely populated sub-distribution board. Mechanical service life typical 10 000 operating cycles — sufficient for most fixed-installation switching duties where the breaker is operated only for isolation or fault reset, not daily load switching. Halogen-free and silicon-free construction meets material restrictions for clean-room or sensitive electronics areas.

Frequently asked questions

What is the breaking capacity of 5SL6206-7?

Rated 6 kA per both EN 60898 and IEC 60947-2 at 400 V AC. That covers residential and light commercial panel fault levels; for higher prospective short-circuit currents (e.g., 10 kA), consider the 5SL4363-7 sibling which carries a 10 kA rating but uses a 3-pole form factor.

Where can I buy 5SL6206-7?

Sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — no stock figures or lead-time numbers are published here.

Will 5SL6206-7 drop into a panel specified around 5SL4363-7?

Not without rewiring. The 5SL6206-7 is 2-pole (36 mm wide), while the 5SL4363-7 is 3-pole (54 mm wide). Both share the same 76 mm depth and 90 mm height, so the panel cutout and rail position are compatible, but the pole count and busbar arrangement differ.

MPN
5SL6206-7