Siemens 5SL6210-6MB — 2-Pole MCB (DIN Rail)

Siemens 5SL6210-6MB SENTRON MCB, 2P B 10A, 6kA

MPN5SL6210-6MB
Active

Siemens SENTRON 5SL6210-6MB, miniature circuit breaker, 2-pole, B characteristic, 10 A, 6 kA per EN 60898 at 400 V AC, 2 MW.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SL6210-6MB — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentResidential buildings/infrastructure
5SL6210-6MB — Electrical
ParameterValue
Number of poles2
5SL6210-6MB — Protection
ParameterValue
Tripping characteristic classB
Overvoltage categoryIII
5SL6210-6MB — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SL6210-6MB — Environmental
ParameterValue
Pollution degree2
5SL6210-6MB — Specifications
ParameterValue
Energy Limitation ClassNo

Product details

The Siemens 5SL6210-6MB is a SENTRON miniature circuit breaker (MCB) with a 2-pole design, B tripping characteristic, and a 10 A rated current at 30 °C. It carries a 6 kA breaking capacity per EN 60898 at 400 V AC, making it suitable for residential and infrastructure branch-circuit protection where moderate fault levels are expected.

B-curve and breaking capacity

The B-curve (tripping characteristic class B) means the magnetic trip operates at 3 to 5 times rated current — 30 to 50 A for this 10 A unit — so it is a good fit for resistive and general-purpose loads where inrush is modest. The 6 kA breaking capacity at 400 V AC (per EN 60898) tells you it can safely interrupt a fault up to that level without upstream damage; the standard certifies it for overcurrent protection in final circuits. Rated voltage for single-phase operation is 250 V AC; multi-phase (line-to-line) goes up to 440 V AC. The DC rating maxes at 72 V, so this is primarily an AC device.

The 5SL6210-6MB snaps onto a standard DIN rail (mounting position any) and occupies 2 modular width units (36 mm total). Depth is 76 mm, height 90 mm, installation depth 70 mm — verify clearance to the enclosure door or gland plate. Sealable, halogen-free, silicon-free — these matter for compliance in clean-room or sensitive environments. Touch protection is built in.

Frequently asked questions

Will 5SL6210-6MB drop into a panel that was specified around 5SL3116-6MB without rewiring?

No — the 5SL6210-6MB is 2-pole and 36 mm wide (2 MW), whereas the 5SL3116-6MB is 1-pole and 18 mm wide (1 MW). The panel would need a wider slot or a different DIN-rail arrangement. Both share the same 76 mm depth and 90 mm height, so depth clearance is identical.

What is 5SL6210-6MB's listed depth?

The depth is 76 mm, installation depth 70 mm.

How do I get current pricing and availability for 5SL6210-6MB?

Sourced and quoted to order against an RFQ through independent distribution — availability and current pricing are confirmed at quote time.