Skip to main content
Siemens 5SL6213-6 — 2-Pole MCB (DIN Rail)

Siemens 5SL6213-6 SENTRON MCB, 2P B-13A 6kA

MPN5SL6213-6
Active

Siemens SENTRON 5SL miniature circuit breaker, order code 5SL6213-6, 2-pole, B-characteristic, 13 A rated current, 6 kA breaking capacity per IEC/EN 60898.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SL6213-6 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentResidential buildings/infrastructure
5SL6213-6 — Electrical
ParameterValue
Number of poles2
5SL6213-6 — Protection
ParameterValue
Tripping characteristic classB
Overvoltage categoryIII
5SL6213-6 — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SL6213-6 — Environmental
ParameterValue
Pollution degree2
5SL6213-6 — Specifications
ParameterValue
Energy Limitation Class3

Product details

Rated for the line — 13 A B-curve, 2-pole

The Siemens 5SL6213-6 is a 2-pole miniature circuit breaker from the SENTRON 5SL series, rated 13 A with a B tripping characteristic and a 6 kA breaking capacity per EN 60898 and IEC 60947-2. At 40 °C ambient the continuous rating derates to 12.37 A; at 55 °C it drops to 11.36 A, so plan your load margin if the panel runs hot.

Installation depth 70 mm leaves clearance behind the rail. Sealable, halogen-free, silicon-free — suitable for clean-room or low-outgassing environments.

Regulatory and compliance posture

The product designation follows IEC 81346-2 and DIN EN 61346-2 (function code F). Touch protection is built in.

Frequently asked questions

What is the breaking capacity of 5SL6213-6?

6 kA per EN 60898 and IEC 60947-2, which covers most residential and light commercial fault levels.

Will 5SL6213-6 drop into a panel specified around 5SL4120-7CC?

Both are 2-pole SENTRON MCBs on the same DIN-rail footprint, but the 5SL4120-7CC is a 20 A C-curve — different rating and trip characteristic. The 5SL6213-6 is 13 A B-curve; verify the branch circuit's load and coordination study before swapping.

Where can I buy 5SL6213-6 and get current pricing?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
5SL6213-6