Skip to main content
Siemens 5SL6216-7 — 2-Pole MCB (DIN Rail)

Siemens 5SL6216-7 SENTRON MCB, 2P C 16A 6kA 400V

MPN5SL6216-7
Active

Siemens SENTRON miniature circuit breaker, 5SL6216-7, 2-pole, C-curve, 16 A, 6 kA breaking capacity at 400 V AC, 50/60 Hz.

$8.38Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6216-7 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentResidential buildings/infrastructure
5SL6216-7 — Electrical
ParameterValue
Number of poles2
Supply voltage at AC rated value400 V
5SL6216-7 — Protection
ParameterValue
Tripping characteristic classC
Overvoltage categoryIII
5SL6216-7 — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SL6216-7 — Environmental
ParameterValue
Pollution degree2
5SL6216-7 — Specifications
ParameterValue
According to EN 60898 rated value6 kA
Energy Limitation Class3

Product details

The Siemens 5SL6216-7 is a SENTRON miniature circuit breaker (MCB), 2-pole, with a C tripping characteristic rated at 16 A. It breaks fault currents up to 6 kA at 400 V AC per both EN 60898 and IEC 60947-2 — the dual rating means it's accepted for residential/infrastructure branch circuits as well as industrial panel feeder protection.

Mounting position any, which simplifies layout in tight enclosures. Sealable design allows lockout-tagout on the toggle.

Environmental and service limits

Rated for -40 °C to 75 °C ambient, pollution degree 2, overvoltage category III. Mechanical service life 10 000 operating cycles typical. Power loss 1.8 W per pole at rated current in hot state, so two poles dissipate about 3.6 W inside the enclosure at full load.

Frequently asked questions

What is the breaking capacity of the 5SL6216-7?

6 kA at 400 V AC per both EN 60898 and IEC 60947-2. That dual rating covers residential/infrastructure branch circuits and industrial panel feeder protection.

Will the 5SL6216-7 fit a panel designed for the 5SL6120-7?

No — the 5SL6216-7 is 2-pole (36 mm wide) versus the 5SL6120-7's 1-pole (18 mm). Same depth and height, so it fits the same DIN rail depth, but the width doubles. Rewiring is required because the pole count differs.

Where can I buy the 5SL6216-7?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

MPN