Skip to main content
Siemens 5SL6216-7CC — 2-Pole MCB (DIN Rail)

Siemens 5SL6216-7CC SENTRON MCB, 2-Pole C 16A 6kA

MPN5SL6216-7CC
Active

Siemens SENTRON 5SL6216-7CC miniature circuit breaker, 2-pole, C-curve, 16 A, 6 kA breaking capacity per EN 60898, 400 V AC, 2 MW.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6216-7CC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentResidential buildings/infrastructure
5SL6216-7CC — Electrical
ParameterValue
Number of poles2
Supply voltage at AC rated value400 V
5SL6216-7CC — Protection
ParameterValue
Tripping characteristic classC
Overvoltage categoryIII
5SL6216-7CC — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SL6216-7CC — Environmental
ParameterValue
Pollution degree2
At 30 °C rated value16 A
5SL6216-7CC — Specifications
ParameterValue
At AC rated value16 A
According to EN 60898 rated value6 kA
Energy Limitation Class3

Product details

What it is and what it does

The Siemens 5SL6216-7CC is a SENTRON miniature circuit breaker (MCB) — a 2-pole, C-curve device rated 16 A at 400 V AC with a 6 kA breaking capacity per EN 60898. That C-curve means it trips between 5× and 10× rated current, so it handles moderate inrush from motor starters or lighting ballasts without nuisance tripping. The 6 kA rating tells you it safely interrupts a fault up to that level under standard residential or light-commercial fault conditions.

Where it goes and how it fits

This MCB snaps onto a standard DIN rail — 2 modular width units (36 mm wide) — and accepts supplementary devices (auxiliary contacts, shunt trips, alarm switches) on the right side. Mounting position is any, so it works in vertical or horizontal panel layouts. The 76 mm depth (70 mm installation depth) leaves clearance for wiring and busbar connections in a standard distribution board.

Thermal derating — the real-world current

Rated 16 A at 30 °C ambient. In a warm enclosure at 40 °C, expect 15.28 A; at 50 °C, 14.53 A; at 55 °C, 14.14 A. If your panel runs hot, size the upstream protection for the derated figure, not the 16 A label.

Frequently asked questions

What is 5SL6216-7CC's depth and width?

Depth is 76 mm (installation depth 70 mm); width is 36 mm (2 modular units).

Where can I buy 5SL6216-7CC?

This part is sourced to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.

What compliance documentation does Siemens provide for 5SL6216-7CC?

The MCB is halogen-free and silicon-free, and rated for pollution degree 2, overvoltage category III, and IP20 with connected conductors. It carries the SENTRON brand and is designed for residential buildings and infrastructure per EN 60898.

MPN
5SL6216-7CC