Siemens 5SL6216-7MB — 2-Pole MCB (DIN Rail)

Siemens 5SL6216-7MB SENTRON MCB, 2P C-16A, 6kA

MPN5SL6216-7MB
Active

Siemens SENTRON 5SL6216-7MB, miniature circuit breaker, 2-pole, C characteristic, 16 A rated current, 6 kA breaking capacity per EN 60898, 400 V AC, 2 MW.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6216-7MB — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentResidential buildings/infrastructure
5SL6216-7MB — Electrical
ParameterValue
Number of poles2
Supply voltage at AC rated value400 V
5SL6216-7MB — Protection
ParameterValue
Tripping characteristic classC
Overvoltage categoryIII
5SL6216-7MB — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SL6216-7MB — Environmental
ParameterValue
Pollution degree2
5SL6216-7MB — Specifications
ParameterValue
According to EN 60898 rated value6 kA
With single-phase operation at AC rated value250 V
Energy Limitation Class3

Product details

The Siemens 5SL6216-7MB is a SENTRON miniature circuit breaker rated 16 A with a C tripping characteristic, designed for 2-pole (1P+N) protection in 400 V AC systems. Its 6 kA breaking capacity per EN 60898 covers the majority of residential and light commercial service-entrance fault levels, while the C-curve (5–10× In magnetic trip) handles motor and lighting inrush without nuisance tripping on moderate-starting loads. Occupying 2 modular width units (36 mm) on a DIN rail, it fits standard distribution boards with a 70 mm installation depth behind the panel cover.

The C-curve (5–10× In) means the magnetic trip activates between 80 A and 160 A for this 16 A breaker — suited for circuits with moderate inrush like small motors, transformers, or capacitor banks, but not for pure resistive loads where a B-curve would give tighter protection. The 6 kA breaking capacity per EN 60898 is the rated short-circuit capacity at 400 V; at lower fault currents the breaker clears faster, but the 6 kA figure is the maximum fault it can safely interrupt without welding contacts or rupturing the case. Power loss per pole is 1.7 W at rated current in hot state, so a 2-pole breaker dissipates about 3.4 W internally — factor that into enclosure thermal calculations if the board is densely populated.

Temperature range and environmental tolerance

Rated for ambient temperatures from -40 °C to +75 °C, with pollution degree 2 and overvoltage category III — suitable for unheated enclosures in cold climates and for main distribution panels where transient overvoltages are expected.

Frequently asked questions

What is the breaking capacity of 5SL6216-7MB?

The breaking capacity is 6 kA according to EN 60898 at 400 V AC. This covers standard residential and light commercial fault levels.

Where can I buy 5SL6216-7MB?

Sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.

What is the difference between 5SL6216-7MB and 5SL4363-7?

The 5SL4363-7 is a 3-pole version with a 10 kA breaking capacity (vs. 2-pole, 6 kA for the 5SL6216-7MB). It occupies 3 MW (54 mm) instead of 2 MW (36 mm). The 5SL6216-7MB will not drop into a panel wired for a 3-pole breaker without rewiring the neutral and adding a pole.