Skip to main content
Siemens 5SL6220-7 — 2-Pole MCB (DIN Rail)

Siemens 5SL6220-7 SENTRON MCB, 2P C-Curve 20A 6kA

MPN5SL6220-7
Active

Siemens SENTRON 5SL6220-7, miniature circuit breaker, 2-pole, C-curve, 20 A, 6 kA breaking capacity, 400 V AC, 2 MW, IP20 with connected conductors.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6220-7 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentResidential buildings/infrastructure
5SL6220-7 — Electrical
ParameterValue
Number of poles2
Supply voltage at AC rated value400 V
5SL6220-7 — Protection
ParameterValue
Tripping characteristic classC
Overvoltage categoryIII
5SL6220-7 — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SL6220-7 — Environmental
ParameterValue
Pollution degree2
5SL6220-7 — Specifications
ParameterValue
According to EN 60898 rated value6 kA
Energy Limitation Class3

Product details

The Siemens 5SL6220-7 is a SENTRON 2-pole miniature circuit breaker rated 20 A with a C tripping characteristic and 6 kA breaking capacity per both EN 60898 and IEC 60947-2. This is the part you spec into a residential or light-commercial distribution board where the branch circuit needs overcurrent and short-circuit protection on a 400 V AC three-phase system.

Snaps onto standard DIN rail; mounting position any.

In a residential or light-commercial main distribution board with a typical upstream transformer impedance, that covers the majority of installation scenarios. The 2-pole design switches both phase and neutral — required for single-phase branch circuits where the neutral is switched. Sealable terminals (yes) allow a lockout-tagout seal across the screw terminals for isolation verification.

Frequently asked questions

What is the breaking capacity of 5SL6220-7?

6 kA per both EN 60898 and IEC 60947-2 at 400 V AC. That's the standard breaking capacity for residential and light-commercial distribution boards.

What is the width of 5SL6220-7?

36 mm, which is 2 modular width units on a standard DIN rail. Depth is 76 mm, installation depth 70 mm.

Where can I buy 5SL6220-7 and how is it quoted?

Sourced to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for your volume and delivery requirements.

MPN