Siemens 5SL6220-7MB — 2-Pole MCB (DIN Rail)

Siemens 5SL6220-7MB SENTRON MCB, 2P C20, 6kA, 400V

MPN5SL6220-7MB
Active

Siemens SENTRON 5SL6220-7MB, miniature circuit breaker, 2-pole, C-curve, 20 A rated current, 6 kA breaking capacity at 400 V AC per EN 60898, 2 MW units wide.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6220-7MB — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentResidential buildings/infrastructure
5SL6220-7MB — Electrical
ParameterValue
Number of poles2
Supply voltage at AC rated value400 V
5SL6220-7MB — Protection
ParameterValue
Tripping characteristic classC
Overvoltage categoryIII
5SL6220-7MB — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SL6220-7MB — Environmental
ParameterValue
Pollution degree2
5SL6220-7MB — Specifications
ParameterValue
According to EN 60898 rated value6 kA
With single-phase operation at AC rated value250 V
Energy Limitation Class3

Product details

The Siemens SENTRON 5SL6220-7MB is a 2-pole miniature circuit breaker (MCB) with a C tripping characteristic, rated at 20 A, and a breaking capacity of 6 kA per EN 60898 at 400 V AC. It sits in the SENTRON family, designed for residential and infrastructure branch-circuit protection. The 70 mm installation depth into the panel leaves clearance for wiring and busbar connections. Rated for any mounting position, it's IP20 with conductors connected — standard for enclosed distribution boards.

For a residential or light commercial distribution board with a typical transformer impedance, this is adequate for most final subcircuits. The C-curve holds through the 5–10x In window, so a 20 A breaker won't nuisance-trip on a 100 A inrush for a few milliseconds — that's the design intent for general-purpose and small motor loads. Single-phase operation is rated at 250 V AC. DC operation is limited to 72 V maximum.

The 2 MW width (36 mm) means it occupies two adjacent 18 mm slots — check your distribution board's fill factor before laying out the row. The 70 mm installation depth allows clearance for rear-connected busbars and wiring ducts. Supplementary devices (shunt trips, auxiliary contacts, alarm switches) can be installed on the right side via the product extension interface. Degree of pollution 2 and overvoltage category III ratings confirm it's suitable for fixed-installation distribution boards where transient overvoltages from the mains are expected — typical for building electrical infrastructure.

Frequently asked questions

What is the breaking capacity of the 5SL6220-7MB?

The breaking capacity is 6 kA at 400 V AC per EN 60898, and also 6 kA per IEC 60947-2 for the single-pole variant; the 2-pole unit shares the same 6 kA rating.

How does the 5SL6220-7MB compare to the 5SL6120-7?

The 5SL6120-7 is a single-pole (1P) version of the same SENTRON C-curve MCB, also rated 20 A and 6 kA at 400 V. The key difference is pole count: the 5SL6220-7MB switches both line and neutral (2P), while the 5SL6120-7 switches only one pole. The 5SL6220-7MB occupies 2 MW (36 mm) versus 1 MW (18 mm) for the 1P unit. If your panel layout was specified around the 5SL6120-7, swapping to the 2-pole version requires two slots instead of one — check your DIN rail space and busbar arrangement before substituting.

Where can I buy the 5SL6220-7MB?

The 5SL6220-7MB is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.