Siemens 5SL6240-6 — 2-Pole MCB (DIN Rail)

Siemens 5SL6240-6 SENTRON MCB, 2-pole B 40 A 6 kA

MPN5SL6240-6
Active

Siemens SENTRON 5SL6 series, miniature circuit breaker (MCB), 2-pole, B characteristic, 40 A, 6 kA per EN 60898, 400 V AC, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SL6240-6 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentResidential buildings/infrastructure
5SL6240-6 — Electrical
ParameterValue
Number of poles2
5SL6240-6 — Protection
ParameterValue
Tripping characteristic classB
Overvoltage category3
5SL6240-6 — Mechanical
ParameterValue
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.0.75 mm²
Max.25 mm²
Protection degree (IP)IP20, with connected conductors

Product details

The Siemens 5SL6240-6 is a 2-pole SENTRON miniature circuit breaker from the 5SL6 series, rated 40 A with a B tripping characteristic and a breaking capacity of 6 kA per EN 60898 at 400 V AC. This is the standard MCB for residential and infrastructure branch-circuit protection — think final subcircuits feeding general-purpose socket outlets or lighting in a panelboard. The B-curve (3–5× In) means it trips fast on moderate overloads, so it pairs with resistive and light inductive loads where inrush isn't extreme.

The B-curve (3–5× In) determines the magnetic trip threshold: between 120 A and 200 A instantaneous. That's appropriate for general-purpose circuits feeding multiple outlets or lighting — not for motor circuits where higher inrush (C or D curve) would be needed to avoid nuisance trips. In a domestic or light commercial distribution board this is usually sufficient; if your fault level exceeds 6 kA at the point of installation, you'd need a higher-rated device upstream or a current-limiting backup fuse. The 2-pole configuration (switching both line and neutral, though neutral is not switched separately per) fits single-phase or split-phase circuits where both conductors need overcurrent protection. Rated voltage is 400 V AC between phases, with a maximum of 440 V in multi-phase operation.

Deployment context

Terminal capacity accepts 0.75 mm² to 25 mm² conductors, so it handles both final-circuit wiring and larger feeder tails.

Frequently asked questions

What are the key ratings of 5SL6240-6?

The 5SL6240-6 is a 2-pole miniature circuit breaker rated 40 A with B tripping characteristic, 6 kA breaking capacity per EN 60898, and 400 V AC rated voltage.

Where can I buy 5SL6240-6 and what is the price?

The 5SL6240-6 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What compliance documentation is available for 5SL6240-6?

The 5SL6240-6 is a Siemens SENTRON MCB designed to EN 60898 and IEC 60947-2, with touch protection, halogen-free and silicon-free construction. Standard RoHS and REACH declarations are part of the Siemens documentation package for this series.

Will 5SL6240-6 drop into a panel specified for 5SL6606-7YA?

The 5SL6240-6 and 5SL6606-7YA are both 2-pole SENTRON MCBs on the same DIN-rail footprint, but their ratings differ. The 5SL6240-6 is 40 A B-curve; verify the 5SL6606-7YA's rating before substituting without recalculating the circuit protection.