Siemens 5SL6250-7RC — 2-Pole MCB (DIN Rail)

Siemens 5SL6250-7RC SENTRON MCB, 50 A, 2-Pole, C Curve, 7.5

MPN5SL6250-7RC
Active

Siemens SENTRON 5SL6250-7RC, miniature circuit breaker, 50 A, 2-pole, C characteristic, 7.5 kA per EN 60898, 415 V AC, IP20, 2 MW units.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SL6250-7RC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentResidential buildings/infrastructure
5SL6250-7RC — Electrical
ParameterValue
Number of poles2
5SL6250-7RC — Protection
ParameterValue
Tripping characteristic classC
Overvoltage categoryIII
5SL6250-7RC — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SL6250-7RC — Environmental
ParameterValue
Pollution degree2
5SL6250-7RC — Specifications
ParameterValue
Energy Limitation ClassNo

Product details

The Siemens SENTRON 5SL6250-7RC is a 50 A, 2-pole miniature circuit breaker with a C tripping characteristic and a 7.5 kA breaking capacity rated per EN 60898. It handles 415 V AC across both poles, making it a straight choice for residential and infrastructure subdistribution panels where the load is moderate and the fault level stays under 7.5 kA. The C curve means it tolerates inrush currents 5 to 10 times the 50 A rating before tripping magnetically — sized for mixed lighting and general-purpose circuits that see brief startup draws. On a 50 A circuit, that's 250 to 500 A instantaneous trip threshold; thermal protection handles sustained overloads. Two modular width units (36 mm) snap onto standard DIN rail.

How the 5SL6250-7RC compares to the 5SL6550-7BB

The closest functional peer in the SENTRON 5SL6 family is the 5SL6550-7BB. Both are 50 A, 2-pole, C-curve MCBs in the same 36 mm wide, 76 mm deep housing. The key difference: the 5SL6250-7RC carries a higher breaking capacity — 7.5 kA per EN 60898 versus 6 kA on the 5SL6550-7BB. Below 6 kA, either works; above 7.5 kA, neither does — step up to a higher-rated series. The 5SL6550-7BB also includes neutral conductor switching and derating data at elevated ambient temperatures (46.19 A at 40 °C, 39.81 A at 55 °C) that the 5SL6250-7RC listing does not explicitly publish, though the thermal behavior should be similar given the same enclosure and pole count.

Halogen-free and silicon-free construction, so it won't off-gas corrosive compounds under fault conditions.

Frequently asked questions

Where can I buy the 5SL6250-7RC and how is it quoted?

The 5SL6250-7RC is sourced to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the closest second-source to the 5SL6250-7RC?

The 5SL6550-7BB is the closest functional peer — same 50 A, 2-pole, C-curve, same housing dimensions. The 5SL6250-7RC has a higher breaking capacity (7.5 kA vs 6 kA), so the 5SL6550-7BB is a drop-in replacement only if your available fault current is 6 kA or less.

Will the 5SL6250-7RC fit in a panel designed for the 5SL6550-7BB?

Yes, it drops into the same DIN-rail footprint — both are 36 mm wide (2 MW), 76 mm deep, with identical mounting position and installation depth. No rewiring or panel modification needed.

What compliance documentation does the 5SL6250-7RC carry?

The 5SL6250-7RC is rated per EN 60898 (7.5 kA breaking capacity), carries overvoltage category III and degree of pollution 2. It is halogen-free and silicon-free. Specific RoHS, REACH, and UL documentation should be confirmed at quote time from the supplier.

MPN