Siemens 5SL6301-7CC — 3-Pole MCB (DIN Rail)

Siemens 5SL6301-7CC SENTRON MCB, 3-pole C-curve 1 A, 6 kA

MPN5SL6301-7CC
Active

Siemens SENTRON series, miniature circuit breaker (MCB), 5SL6301-7CC, 3-pole, C-curve, 1 A rated current, 6 kA breaking capacity at 400 V AC, 3 modular width units.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6301-7CC — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Pole configuration3P
Suitability for operationResidential buildings/infrastructure
5SL6301-7CC — Protection
ParameterValue
Tripping characteristic (curve)C
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Energy limitation class3
Pollution degree2
5SL6301-7CC — Electrical
ParameterValue
Rated current (AC)1 A
Rated voltage (AC, multi-phase)440 V
5SL6301-7CC — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
SealableYes
5SL6301-7CC — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens SENTRON 5SL6301-7CC is a 3-pole miniature circuit breaker (MCB) with a C-curve tripping characteristic, rated at 1 A and 400 V AC.

The C-curve means the MCB trips at 5 to 10 times rated current (5–10 A for this 1 A unit), which handles the startup surge of small inductive loads without nuisance tripping. The 6 kA breaking capacity per EN 60898 is the maximum fault current it can safely interrupt at 400 V; this is adequate for most residential and light commercial distribution boards where the prospective short-circuit current stays under that threshold. Thermal derating is significant here: at 40 °C ambient the continuous rating drops to 0.92 A, at 50 °C to 0.84 A, and at 55 °C to 0.79 A. If the panel runs warm, size up or account for the reduced headroom. The 3-pole design (3 modular width units, 54 mm wide) protects a three-phase circuit; the neutral is not switched.

Frequently asked questions

Where can I buy the 5SL6301-7CC and get a price?

This part is sourced to order against an RFQ through independent distribution. Submit a quote request for current availability and pricing.

What is the breaking capacity of the 5SL6301-7CC?

The breaking capacity is 6 kA at 400 V AC per EN 60898, suitable for residential and infrastructure distribution boards.

What is the width of the 5SL6301-7CC in modular units?

It occupies 3 modular width units (54 mm total width) on a DIN rail.

MPN
5SL6301-7CC