Skip to main content
Siemens 5SL6302-7 — Miniature Circuit Breakers (MCB)

Siemens 5SL6302-7 SENTRON MCB, 3P C 2A 6kA 400V

MPN5SL6302-7
Active

Siemens SENTRON 5SL6302-7 miniature circuit breaker, 3-pole, C characteristic, 2 A, 6 kA breaking capacity at 400 V AC, 3 MW units.

$19.05Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SL6302-7 — Ratings
ParameterValue
Overvoltage categoryIII
5SL6302-7 — Mechanical
ParameterValue
Width54 mm
Height90 mm
Depth76 mm

Product details

The Siemens 5SL6302-7 is a SENTRON miniature circuit breaker (MCB) — 3-pole, C-curve, rated 2 A at 400 V AC, with a 6 kA breaking capacity certified to both EN 60898 and IEC 60947-2. That 6 kA rating means it safely clears a fault up to 6,000 A without welding its contacts or cascading damage upstream — the standard for residential and light commercial distribution boards.

The C-curve trips between 5× and 10× rated current — so at 2 A, it holds through motor inrush and capacitive loads that would nuisance-trip a B-curve, but still clears fast on a hard short. The 2 A rating is at 30 °C ambient; at 40 °C it derates to 1.9 A, and at 55 °C to 1.75 A — panel builders need to account for this if the breaker sits in a warm enclosure. It occupies 3 modular width units (54 mm) on a DIN rail, with a depth of 76 mm and an installation depth of 70 mm. The operating temperature range spans -40 °C to 75 °C, with a mechanical service life of 10,000 cycles typical.

The 3-pole design means it needs three adjacent modular spaces — standard for a 3-phase feed. Sealable, halogen-free, silicon-free — relevant for clean-room or food-grade panels where outgassing or tamper evidence matters.

Frequently asked questions

What is the breaking capacity of 5SL6302-7?

6 kA per both EN 60898 and IEC 60947-2 at 400 V AC — standard for residential and light commercial distribution.

What does the C-curve mean on this breaker?

It trips between 5× and 10× rated current (10 A to 20 A for this 2 A unit), so it tolerates motor inrush and transformer energization without nuisance tripping.

Where can I buy 5SL6302-7?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
5SL6302-7