Skip to main content
Siemens 5SL6304-7 — 3-Pole MCB (DIN Rail)

Siemens 5SL6304-7 SENTRON MCB, 3P C 4A 6kA

MPN5SL6304-7
Active

Siemens SENTRON 5SL6304-7 miniature circuit breaker, 3-pole, C-curve, 4 A, 400 V AC, 6 kA breaking capacity per EN 60898/IEC 60947-2, 3 MW units wide.

$19.05Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6304-7 — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Pole configuration3P
Suitability for operationResidential buildings/infrastructure
5SL6304-7 — Protection
ParameterValue
Tripping characteristic (curve)C
Breaking capacity per EN 608986 kA
Breaking capacity per IEC 60947-26 kA
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Energy limitation class3
Pollution degree2
5SL6304-7 — Electrical
ParameterValue
Rated voltage (AC, multi-phase)440 V
Voltage type (AC/DC)AC
Supply frequency range50/60 Hz
Power loss per pole at rated current (AC, hot)0.7 W
Mechanical service life (operating cycles, typ.)10 000
5SL6304-7 — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
SealableYes
Accepts supplementary devicesYes
5SL6304-7 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes

Product details

The 5SL6304-7: The 4 A C-curve is the key spec: it trips magnetically between 5× and 10× rated current (20–40 A), which is the standard choice for general-purpose lighting and small motor circuits where moderate inrush is expected. The 10,000 mechanical operating cycles typical life is fine for a distribution MCB that sees infrequent switching.

Snap-on DIN rail mount, any position. Three modular width units (54 mm) means it occupies three standard 18 mm slots on the rail. Sealable, halogen-free, silicon-free — relevant for clean-room or food-processing panels where outgassing or contamination is a concern. Accepts auxiliary switches and shunt trips (product extension installable supplementary devices = Yes) for remote status or emergency-off circuits.

Frequently asked questions

What is the breaking capacity of the 5SL6304-7?

6 kA per both EN 60898 and IEC 60947-2 at 400 V AC.

How does the 5SL6304-7 compare to the 5SL4363-7?

The 5SL4363-7 is the same 3-pole C-curve form factor but rated 10 kA breaking capacity instead of 6 kA. The 5SL6304-7 will drop into the same panel footprint — identical dimensions (76 mm depth, 54 mm width), same DIN rail mount, same terminal layout. The only fit difference is the interrupting rating; if the panel's prospective fault current is under 6 kA, the 5SL6304-7 is a direct mechanical and electrical substitute.

Where can I buy the 5SL6304-7?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
5SL6304-7