Skip to main content
Siemens 5SL6306-6 — 3-Pole MCB (DIN Rail)

Siemens 5SL6306-6 SENTRON MCB, 3P B 6A 6kA

MPN5SL6306-6
Active

Siemens SENTRON 5SL6306-6 miniature circuit breaker, 3-pole, B-curve, 6 A rated, 6 kA breaking capacity per EN 60898, 400 V AC.

$13.97Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6306-6 — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Pole configuration3P
Suitability for operationResidential buildings/infrastructure
5SL6306-6 — Protection
ParameterValue
Tripping characteristic (curve)B
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Energy limitation class3
Pollution degree2
5SL6306-6 — Electrical
ParameterValue
Rated current (AC)6 A
Rated voltage (AC, multi-phase)440 V
5SL6306-6 — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
SealableYes
5SL6306-6 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens 5SL6306-6 is a SENTRON miniature circuit breaker rated 6 A at 400 V AC with a B tripping characteristic and 6 kA breaking capacity per EN 60898. It's a 3-pole unit in a 3-module-width housing (54 mm), designed for residential and infrastructure branch-circuit protection where the B-curve handles resistive and light inductive loads without nuisance tripping from inrush.

The B-curve (3-5 In) trips fast on short circuits but holds through normal motor-start inrush for small pumps or fans; it's the standard choice for general-purpose lighting and socket circuits. Thermal derating is published: at 40 °C ambient the continuous rating drops to 5.64 A, at 55 °C to 5.04 A. The breaker mounts in any position and fits a standard DIN rail with 70 mm installation depth.

Sealable terminals are provided, which matters for utility-metering or rental applications where tamper evidence is required. Halogen-free and silicon-free construction meets low-smoke material specs for public-building installations.

Frequently asked questions

Where can I buy the 5SL6306-6 and how is it quoted?

We source the 5SL6306-6 to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the breaking capacity of the 5SL6306-6?

6 kA at 400 V AC per EN 60898, and also rated 6 kA per IEC 60947-2. That's sufficient for most residential and light commercial distribution boards.

What is the width and depth of the 5SL6306-6?

Width is 54 mm (3 modular units), depth is 76 mm. Installation depth on the DIN rail is 70 mm.

Will the 5SL6306-6 drop into a panel specified for the 5SL3340-7CC?

Both are 3-pole SENTRON MCBs on the same DIN-rail footprint, but the 5SL3340-7CC is a C-curve 40 A unit with a different breaking capacity. The 5SL6306-6 is B-curve 6 A — they are not electrically interchangeable without recalculating the load and coordination study.

MPN
5SL6306-6