Skip to main content
Siemens 5SL6306-7RC — 3-Pole MCB (DIN Rail)

Siemens 5SL6306-7RC SENTRON MCB 6A 3P C 7.5kA

MPN5SL6306-7RC
Active

Siemens SENTRON 5SL6306-7RC, miniature circuit breaker, 6A, 3-pole, C characteristic, 7.5kA breaking capacity per EN 60898, 415V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6306-7RC — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Pole configuration3P
Suitability for operationResidential buildings/infrastructure
5SL6306-7RC — Protection
ParameterValue
Tripping characteristic (curve)C
Breaking capacity per EN 608987.5 kA
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Energy limitation classNo
Pollution degree2
5SL6306-7RC — Electrical
ParameterValue
Rated voltage (AC, multi-phase)440 V
Voltage type (AC/DC)AC
Supply frequency range50/60 Hz
Power loss per pole at rated current (AC, hot)0.86 W
Mechanical service life (operating cycles, typ.)10 000
Rated voltage (AC, single-phase)250 V
5SL6306-7RC — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
SealableYes
Accepts supplementary devicesYes
5SL6306-7RC — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes

Product details

What this MCB is and what the ratings mean

The Siemens 5SL6306-7RC is a 6 A, 3-pole miniature circuit breaker from the SENTRON family, with a C tripping characteristic and a 7.5 kA breaking capacity rated per EN 60898 at 415 V AC. The C curve means it tolerates brief inrush currents 5 to 10 times the rated current — standard for mixed resistive and light inductive loads like lighting circuits, small transformers, and general socket outlets in residential or light commercial distribution boards. The 7.5 kA short-circuit capacity is the maximum fault current it can safely interrupt at the rated voltage; for panels fed by a transformer with higher prospective fault current, you'd need a current-limiting upstream device or a breaker with a higher kA rating.

Integration and panel fit

Occupies 3 modular width units (54 mm total) on a DIN rail, with a depth of 76 mm and an installation depth of 70 mm. Mounting position is any — no derating required for upside-down or sideways installation in a tight enclosure. IP20 with connected conductors, so it's protected against finger contact but not washdown; install inside a distribution board or enclosure rated for the environment. Sealable, halogen-free, and silicon-free — important for environments where outgassing or silicone contamination matters (e.g., near sensitive contacts or in clean-ish industrial zones).

Frequently asked questions

Where can I buy 5SL6306-7RC and how do I get a price?

The 5SL6306-7RC is sourced and quoted to order against an RFQ through independent distribution. Submit a request for quote to confirm availability and current pricing.

When sourcing 5SL6306-7RC, what's the closest functional alternative — 5SL4363-7?

The 5SL4363-7 is a close sibling: same 3-pole C-curve, same 6 A rating, same mechanical footprint (76 mm depth, 54 mm width, 3 MW). The key difference is breaking capacity — the 5SL4363-7 is rated 10 kA per both EN 60898 and IEC 60947-2, versus 7.5 kA for the 5SL6306-7RC. It also carries an Energy Limitation Class of 3 (the 5SL6306-7RC does not list one), and its per-pole power loss at rated current is higher at 5 W versus 0.86 W. Panel cutout and wiring are identical, but the 5SL4363-7 runs hotter and requires a higher fault-current rating upstream.

Will 5SL6306-7RC drop into a panel that was specified around 5SL4363-7 without rewiring?

Yes, the physical dimensions are identical: same 76 mm depth, 54 mm width, 70 mm installation depth, and 3 modular width units. DIN-rail clip and terminal layout match. No rewiring needed for the swap, but verify the panel's prospective short-circuit current does not exceed 7.5 kA at 415 V — the 5SL4363-7 was rated for 10 kA, so the 5SL6306-7RC has less headroom.

What compliance documentation does Siemens provide for 5SL6306-7RC?

The 5SL6306-7RC is halogen-free and silicon-free, which supports RoHS and REACH compliance. The IP20 rating and Overvoltage Category III indicate it meets IEC 60947-2 and EN 60898 construction standards. Declaration of conformity and CE marking documentation are available through Siemens channels.

MPN
5SL6306-7RC