Skip to main content
Siemens 5SL6310-6 — Miniature Circuit Breakers (MCB)

Siemens 5SL6310-6 SENTRON MCB, 3P B-10A 6kA 400V

MPN5SL6310-6
Active

Siemens SENTRON 5SL6310-6 miniature circuit breaker, 3-pole, B-characteristic, 10 A rated current, 6 kA breaking capacity at 400 V AC, 3 MW.

$11.43Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SL6310-6 — Ratings
ParameterValue
Overvoltage categoryIII
5SL6310-6 — Mechanical
ParameterValue
Width54 mm
Height90 mm
Depth76 mm

Product details

The Siemens 5SL6310-6 is a SENTRON miniature circuit breaker (MCB) with a 3-pole design, B tripping characteristic, and a 10 A rated current at 400 V AC. Its 6 kA breaking capacity, certified per both EN 60898 and IEC 60947-2, handles standard residential and infrastructure branch-circuit faults without cascading upstream. The B-curve trips between 3 and 5 times rated current, making it a fit for resistive and general-purpose loads where inrush is moderate — think lighting, socket outlets, or control transformers. Rated for 50/60 Hz networks, it occupies 3 modular width units (54 mm) on a DIN rail.

Thermal derating and real-world current

The 10 A rating holds at 30 °C ambient. At 40 °C it derates to 9.52 A, at 45 °C to 9.2 A, and at 55 °C to 8.74 A. If the panel runs warm — common in a crowded enclosure — the continuous load should be sized against the derated figure, not the 30 °C number. The 1.6 W power loss per pole at rated current in hot operating state adds up; for a 3-pole breaker that's 4.8 W dissipated inside the enclosure, so ventilation or spacing matters when grouping several MCBs.

Panel integration and environmental limits

Mounts in any position on a DIN rail; the 54 mm width (3 MW) and 76 mm depth fit standard distribution boards. Installation depth is 70 mm. Rated IP20 with connected conductors — fine for enclosed panels, not for washdown zones. The operating temperature range spans -40 °C to 75 °C, covering most indoor and sheltered outdoor cabinets. Pollution degree 2 and overvoltage category III are typical for fixed-installation branch circuits. Sealable, halogen-free, and silicon-free construction matters for environments sensitive to outgassing (clean rooms, medical, or certain industrial zones).

Supplementary devices and mechanical endurance

The design accepts installable supplementary devices (auxiliary switches, shunt trips, alarm contacts) — useful for remote status or emergency-off integration. Mechanical service life is rated at 10,000 operating cycles typical, which covers routine switching for a panel's service life. Energy limitation class 3 means it limits let-through energy well, reducing stress on downstream equipment during a fault.

Frequently asked questions

What is the breaking capacity of the 5SL6310-6?

The breaking capacity is 6 kA, certified per both EN 60898 and IEC 60947-2 at 400 V AC.

What is the 5SL6310-6 used for?

It is a miniature circuit breaker for residential buildings and infrastructure, protecting branch circuits against overloads and short circuits with a B tripping characteristic.

What is the closest functional second-source to the 5SL6310-6?

The 5SL4363-7 is a peer MPN in the same SENTRON family, but verify the tripping characteristic and breaking capacity against your specific BOM before substituting. The 5SL6310-6 uses a B-curve; the peer may differ.

Where can I buy the 5SL6310-6?

The 5SL6310-6 is sourced to order through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time.

MPN
5SL6310-6