Skip to main content
Siemens 5SL6310-7 — 3-Pole MCB (DIN Rail)

Siemens 5SL6310-7 SENTRON MCB, 3P C 10A 6kA 400V

MPN5SL6310-7
Active

Siemens SENTRON 5SL6310-7, miniature circuit breaker, 3-pole, C-curve, 10 A, 6 kA breaking capacity at 400 V AC, 3 modular width units.

$12.19Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6310-7 — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Pole configuration3P
Suitability for operationResidential buildings/infrastructure
5SL6310-7 — Protection
ParameterValue
Tripping characteristic (curve)C
Breaking capacity per EN 608986 kA
Breaking capacity per IEC 60947-26 kA
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Energy limitation class3
Pollution degree2
5SL6310-7 — Electrical
ParameterValue
Rated voltage (AC, multi-phase)440 V
Voltage type (AC/DC)AC
Supply frequency range50/60 Hz
Power loss per pole at rated current (AC, hot)1.3 W
Mechanical service life (operating cycles, typ.)10 000
5SL6310-7 — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
SealableYes
Accepts supplementary devicesYes
5SL6310-7 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens SENTRON 5SL6310-7 is a 3-pole miniature circuit breaker (MCB) with a C tripping characteristic, rated 10 A and a 6 kA breaking capacity at 400 V AC. For a 3-pole device on a 400 V three-phase supply, that covers the vast majority of commercial and light industrial panelboards. The 10 A rating at the hot operating state dissipates 1.3 W per pole — useful to know for thermal budgeting inside a crowded enclosure.

Panel integration and mounting notes

Snap-on mounting for DIN rail (EN 60715). Mounting position is any, so vertical or horizontal rail orientation is fine.

Siemens designates this for residential buildings and infrastructure — think apartment distribution boards, small commercial panels, lighting circuits, and general-purpose socket outlets. The 10 A C-curve is a common choice for lighting final circuits and small appliance loads in European-style panelboards.

Frequently asked questions

What is the breaking capacity of the 5SL6310-7?

6 kA per both EN 60898 and IEC 60947-2 at 400 V AC. That's the standard breaking capacity for this class of MCB in residential and light commercial distribution.

Will the 5SL6310-7 fit in a panel designed for the 5SL4363-7?

Yes, the 5SL6310-7 and 5SL4363-7 share identical dimensions (76 mm depth, 54 mm width, 90 mm height), the same 3-pole form factor, and the same DIN-rail mounting. The key difference is breaking capacity: the 5SL4363-7 is rated 10 kA, while the 5SL6310-7 is rated 6 kA. If the panel's fault-current rating is 6 kA or less, it drops in without rewiring.

Where can I buy the 5SL6310-7?

We source and quote the 5SL6310-7 to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment.

MPN