Skip to main content
Siemens 5SL6310-7BB — 3-Pole MCB (DIN Rail)

Siemens 5SL6310-7BB SENTRON MCB, 3P C 10A, 6kA

MPN5SL6310-7BB

Siemens SENTRON 5SL6310-7BB, miniature circuit breaker, 3-pole, C-curve, 10 A rated, 6 kA breaking capacity per EN 60898, 400 V AC, 3 modular width units.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6310-7BB — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Pole configuration3P
Suitability for operationResidential buildings/infrastructure
5SL6310-7BB — Protection
ParameterValue
Tripping characteristic (curve)C
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Energy limitation class3
Pollution degree2
5SL6310-7BB — Electrical
ParameterValue
Rated current (AC)10 A
Rated voltage (AC, multi-phase)440 V
5SL6310-7BB — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
SealableYes
5SL6310-7BB — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes

Product details

What it is and what it does

The Siemens 5SL6310-7BB is a SENTRON miniature circuit breaker (MCB) — 3-pole, C-curve, rated 10 A at 400 V AC, with a 6 kA breaking capacity per EN 60898 and IEC 60947-2. That C-curve means it trips between 5 and 10 times rated current, so it's the go-to for general-purpose loads like lighting, socket circuits, and small motor starters where you need moderate inrush tolerance without sacrificing fault protection.

Temperature derating — what the numbers mean

At 30 °C ambient the breaker holds its full 10 A rating. At 40 °C it's down to 9.24 A, at 45 °C to 8.8 A, and at 55 °C to 7.96 A. If your panel runs hot — say inside a non-climate-controlled enclosure near a furnace line — you need to size up one frame or accept the derated continuous current. The mechanical life is 10 000 switching cycles typical, which is fine for most distribution panels but not for daily switching duty.

Mounting and integration

Snaps onto standard DIN rail, any mounting position. It takes 3 modular width units (each 18 mm, so 54 mm total). Depth is 76 mm, installation depth 70 mm — verify your enclosure depth if you're retrofitting into a shallow gland box. IP20 with connected conductors, so it's for enclosed panels only, not washdown areas. Pollution degree 2, overvoltage category III — standard for fixed-installation distribution boards.

Frequently asked questions

What is the breaking capacity of 5SL6310-7BB?

6 kA per both EN 60898 and IEC 60947-2 at 400 V AC. That's sufficient for most residential and light commercial distribution boards where the prospective short-circuit current stays under 6 kA.

Will 5SL6310-7BB drop into a panel specified for 5SL4363-7?

Both are 3-pole SENTRON MCBs with the same 54 mm width (3 modular units) and DIN-rail mount. The 5SL4363-7 is a different rating/curve variant; check the specific current and characteristic before swapping. Mechanically they share the same footprint.

Where can I buy 5SL6310-7BB and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock figures or price lists are published here.

MPN
5SL6310-7BB