Siemens 5SL6316-6BB — 3-Pole MCB (DIN Rail)

Siemens 5SL6316-6BB SENTRON MCB, 3P B-Char 16A 6kA

MPN5SL6316-6BB

Siemens SENTRON 5SL6316-6BB, miniature circuit breaker, 3-pole, B characteristic, 16 A, 6 kA breaking capacity per EN 60898, 400 V AC, 3 MW units.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6316-6BB — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Pole configuration3P
Suitability for operationResidential buildings/infrastructure
5SL6316-6BB — Protection
ParameterValue
Tripping characteristic (curve)B
Breaking capacity per EN 608986 kA
Breaking capacity per IEC 60947-26 kA
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Energy limitation class3
Pollution degree2
5SL6316-6BB — Electrical
ParameterValue
Rated voltage (AC, multi-phase)440 V
Voltage type (AC/DC)AC
Supply frequency range50/60 Hz
Power loss per pole at rated current (AC, hot)1.8 W
Mechanical service life (operating cycles, typ.)10 000
5SL6316-6BB — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
SealableYes
Accepts supplementary devicesYes
5SL6316-6BB — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes

Product details

Siemens 5SL6316-6BB SENTRON MCB — 3-pole B-curve 16 A, 6 kA

The Siemens 5SL6316-6BB is a 3-pole miniature circuit breaker from the SENTRON 5SL series, rated 16 A with a B tripping characteristic and a 6 kA breaking capacity per EN 60898 (also 6 kA per IEC 60947-2). It is designed for 400 V AC multi-phase operation, handles 50/60 Hz, and occupies 3 modular width units (54 mm) on a DIN rail.

The 1.8 W power loss per pole at rated current in hot operating state is modest — 5.4 W total for the 3-pole unit — so derating within a multi-device enclosure is manageable. The mechanical service life of 10 000 operating cycles is typical for this class; the part is not intended for frequent switching duty (use a contactor for that).

The part carries the Italy-specific version suffix (6BB), which typically affects packaging language and regional catalog listing — the functional ratings are identical to the standard 5SL6316-6 variant. For BOM traceability, the nameplate matches the order code exactly; no substitution without requalification.

Panel integration

Depth is 76 mm (installation depth 70 mm behind the panel surface), width 54 mm (3 MW units), height 90 mm. The 3-pole footprint matches the standard SENTRON 5SL family — same housing dimensions as the 5SL4363-7 (C-curve, 10 kA) and the 5SL6120-7 (1-pole, C-curve).

Frequently asked questions

What is the breaking capacity of the 5SL6316-6BB?

6 kA per EN 60898 and also 6 kA per IEC 60947-2, at 400 V AC.

Will the 5SL6316-6BB drop into a panel specified for the 5SL4363-7?

Yes — same DIN-rail footprint, same 3-pole housing dimensions (76 mm depth, 54 mm width, 90 mm height), same mounting position flexibility. The difference is the tripping curve (B vs C) and the breaking capacity (6 kA vs 10 kA). The 5SL4363-7 is a C-curve 63 A unit with 10 kA; the 5SL6316-6BB is a B-curve 16 A unit with 6 kA. If the panel was designed for a 3-pole SENTRON MCB, the 5SL6316-6BB fits mechanically, but the electrical ratings must match the circuit design.

Where can I buy the 5SL6316-6BB?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead-time estimate.

What compliance documentation does Siemens provide for the 5SL6316-6BB?

The part is halogen-free and silicon-free. It carries the CE mark for the European market, and the 6 kA rating is certified per EN 60898 and IEC 60947-2. RoHS and REACH declarations are standard from Siemens for the SENTRON series.

MPN