Siemens 5SL6332-6CC — 3-Pole MCB (DIN Rail)

Siemens SENTRON 5SL6332-6CC MCB, 3P, B Curve, 32 A, 6 kA

MPN5SL6332-6CC
Active

Siemens SENTRON 5SL6332-6CC miniature circuit breaker, 3-pole, B characteristic, 32 A rated current, 400 V AC, 6 kA breaking capacity per EN 60898.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6332-6CC — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Pole configuration3P
Suitability for operationResidential buildings/infrastructure
5SL6332-6CC — Protection
ParameterValue
Tripping characteristic (curve)B
Breaking capacity per EN 608986 kA
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Energy limitation class3
Pollution degree2
5SL6332-6CC — Electrical
ParameterValue
Rated voltage (AC, multi-phase)440 V
Voltage type (AC/DC)AC
Supply frequency range50/60 Hz
Power loss per pole at rated current (AC, hot)4.6 W
5SL6332-6CC — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
SealableYes
Accepts supplementary devicesYes
5SL6332-6CC — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Vibration resistance (IEC 60068-2-6)50 m/s² at 25 to 150 Hz

Product details

The Siemens SENTRON 5SL6332-6CC is a 3-pole miniature circuit breaker (MCB) with a B tripping characteristic, rated 32 A at 400 V AC and a breaking capacity of 6 kA according to EN 60898. The 6 kA breaking capacity at 400 V tells you it can safely interrupt a fault current up to 6,000 A without welding contacts or cascading failure upstream — adequate for most final subcircuits in a TN or TT system where the prospective short-circuit current stays under that threshold. Rated for 50/60 Hz supply, the 5SL6332-6CC accepts up to 440 V AC in multi-phase operation.

Width is 54 mm — that's 3 modular width units at 18 mm each, so it occupies three adjacent slots in the distribution board. Depth is 76 mm, installation depth 70 mm; the 90 mm height leaves clearance for most enclosure lids with busbar shrouds. Mounting position is any, which simplifies layout in crowded panels. Sealable design allows tamper-proofing with a lead seal wire through the housing. Vibration resistance tested to 50 m/s² at 25 to 150 Hz per IEC 60068-2-6 — it holds up on machine-mounted sub-distribution near pumps or conveyors.

Frequently asked questions

Will 5SL6332-6CC drop into a panel specified around 5SL4363-7 without rewiring?

Yes — the two share the same physical footprint (54 mm width, 76 mm depth, 90 mm height), same DIN-rail mounting, and same 3-pole busbar pitch. No enclosure modification or rewiring is needed for the swap. The only change is the tripping curve (B vs C) and the breaking capacity rating, which affects coordination with upstream devices, not the physical fit.