Skip to main content
Siemens 5SL6363-7CC — 3-Pole MCB (DIN Rail)

Siemens 5SL6363-7CC SENTRON MCB, 3P C 63A 400V 6kA

MPN5SL6363-7CC
Active

Siemens SENTRON 5SL6363-7CC miniature circuit breaker, 3-pole, C-curve, 63 A, 400 V AC, 6 kA breaking capacity per EN 60898, 3 modular width units.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6363-7CC — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Pole configuration3P
Suitability for operationResidential buildings/infrastructure
5SL6363-7CC — Protection
ParameterValue
Tripping characteristic (curve)C
Breaking capacity per EN 608986 kA
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Energy limitation class3
Pollution degree2
5SL6363-7CC — Electrical
ParameterValue
Rated voltage (AC, multi-phase)440 V
Voltage type (AC/DC)AC
Supply frequency range50/60 Hz
Power loss per pole at rated current (AC, hot)5 W
5SL6363-7CC — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
SealableYes
Accepts supplementary devicesYes
5SL6363-7CC — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Vibration resistance (IEC 60068-2-6)50 m/s² at 25 to 150 Hz

Product details

The Siemens SENTRON 5SL6363-7CC is a 3-pole miniature circuit breaker rated 63 A with a C tripping characteristic, designed for 400 V AC systems and a 6 kA breaking capacity per EN 60898. It occupies 3 modular width units (54 mm) on a DIN rail, with a depth of 76 mm and an installation depth of 70 mm — standard panel fit for a 3P MCB in this class.

The 3-pole design switches all three phases simultaneously, which is the expected configuration for a 400 V three-phase feeder or submain in a distribution board.

This MCB is specified for residential buildings and infrastructure — think apartment distribution boards, small commercial panelboards, and lighting circuits in public facilities. Mounting position is unrestricted, so it works in vertical or horizontal DIN-rail enclosures.

Halogen-free and silicon-free construction matters in clean-room or sensitive-electronic environments where outgassing from a fault could contaminate contacts or optics. The sealable design allows the panel builder to lock the toggle position after commissioning, preventing unauthorized switching.

Frequently asked questions

What is the breaking capacity of 5SL6363-7CC?

6 kA per EN 60898 at 400 V AC. This is the standard residential/infrastructure rating for this class of MCB.

Will 5SL6363-7CC fit a panel designed for 5SL4363-7?

Yes, the two share identical dimensions (76 mm depth, 54 mm width, 90 mm height, 70 mm installation depth) and the same 3-pole, C-curve, 63 A rating. The difference is breaking capacity: 5SL4363-7 is rated 10 kA per both EN 60898 and IEC 60947-2, while 5SL6363-7CC is rated 6 kA per EN 60898. If the panel was specified around 5SL4363-7 for its higher fault rating, dropping in the 5SL6363-7CC may reduce the SCCR of the assembly — verify the available fault current at the installation point before substituting.

Where can I buy 5SL6363-7CC and get a price?

We source and quote this part to order against an RFQ. Send the quantity and target delivery window; availability and current pricing are confirmed at quote time through independent distribution channels.

MPN
5SL6363-7CC