Siemens 5SL6363-8CC — 3-Pole MCB (DIN Rail)

Siemens 5SL6363-8CC SENTRON MCB, 3-Pole D-Curve 63 A, 6 kA

MPN5SL6363-8CC
Active

Siemens SENTRON 5SL6363-8CC miniature circuit breaker, 3-pole, D tripping characteristic, 63 A rated current, 6 kA breaking capacity at 400 V AC, 3 MW units.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6363-8CC — Identification
ParameterValue
Design / model code5SL6CC
Brand nameSENTRON
Number of poles3
Suitability for operationResidential buildings/infrastructure
5SL6363-8CC — Protection
ParameterValue
Tripping characteristic (curve)D
Breaking capacity per EN 608986 kA
Overvoltage category3
IP protection classIP20, with connected conductors
Pollution degree2
5SL6363-8CC — Electrical
ParameterValue
Rated voltage (AC, multi-phase)440 V
Rated frequency50 Hz
5SL6363-8CC — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
SealableYes
5SL6363-8CC — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of surrounding temperaturePeriodically +55°C, max. 95% humidity

Product details

Siemens 5SL6363-8CC SENTRON MCB — 63 A, D-Curve, 3-Pole

The Siemens 5SL6363-8CC is a SENTRON miniature circuit breaker rated 63 A with a D tripping characteristic, built for 3-pole AC circuits at 400 V. At 63 A, it handles a substantial branch circuit; the 6 kA breaking capacity (per EN 60898) covers most commercial and light industrial fault levels. Rated for ambient temperatures from -40 °C to +75 °C, with periodic humidity up to 55 °C at 95% — fine for outdoor-rated cabinets or unconditioned plant floors.

The D-curve (10–20× In magnetic trip) is the key selection criterion. Standard C-curve breakers trip at 5–10× In and would nuisance-open on a motor start or a large capacitor bank. This 5SL6363-8CC is sized for loads with high inrush but limited fault current — the 6 kA at 400 V AC (per EN 60898) means it safely interrupts faults up to that level without cascading upstream. If your available fault current exceeds 6 kA, you need a higher-rated breaker upstream or a current-limiting device. Rated operational voltage is 400 V AC (3-phase), with a maximum multi-phase voltage of 440 V AC. The 63 A rating is continuous — no derating needed for standard panel ambient up to 40 °C, though the -40 °C to +75 °C range covers extreme environments.

Panel Integration

Three modular-width units (54 mm total) on DIN rail. Sealable — useful for metering or tenant sub-panels where unauthorized switching is a concern. Mounting position any orientation, so horizontal busbars or vertical drops both work. Vibration resistance tested to 50 m/s² at 25–150 Hz per IEC 60068-2-6 — suitable for installation near rotating machinery or on mobile equipment. Halogen-free and silicon-free construction avoids corrosive off-gassing in sealed enclosures.

Frequently asked questions

Will 5SL6363-8CC drop into a panel specified around 5SL3640-7MB?

Both are 3-pole SENTRON MCBs on DIN rail, same modular width. The 5SL6363-8CC is a D-curve 63 A device; the 5SL3640-7MB is a different rating/curve. Physical footprint matches (3 MW units), so no rewiring of the busbar or enclosure is needed — but confirm the trip curve and ampacity match your circuit design before swapping.

MPN
5SL6363-8CC